Evaluation of a single-platform technology for lymphocyte immunophenotyping.

Jeanette Higgins1, Valerie Hill, Karen Lau, Virginia Simpson, Jean Roayaei, Rick Klabansky, Randy A Stevens, Julia A Metcalf, Michael Baseler.   

Abstract

An accurate and reproducible CD4 count is a fundamental clinical tool for monitoring and treating human immunodeficiency virus infection and its complications. Two methods exist for calculating absolute CD4 counts: dual-platform technology (DPT) and single-platform technology (SPT). Numerous studies have documented the unacceptably wide range of variation in absolute CD4 counts between laboratories. SPT was introduced in 1996 to reduce the interlaboratory variation in absolute CD4 counts. The aim of this study was to compare DPT with the BD Biosciences Trucount method (an SPT method). Both the percentages of CD4 (r = 0.986; P = 0.0541) and the absolute CD4 counts (r = 0.960; P = 0.0001) had very good correlation between the two methods. However, poor correlation was observed for the CD8(+) RO(-) (r = 0.314; P = 0.0002), CD8(+) DR(+) (r = 0.666; P = 0.0138), CD3(+) CD38(+) (r = 0.8000; P = 0.0004), CD3(+) CD25(+) (r = 0.464; P = 0.0082), and CD4(+) CD38(+) (r = 0.357; P = 0.0127) measurements.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17761524      PMCID: PMC2168127          DOI: 10.1128/CVI.00168-07

Source DB:  PubMed          Journal:  Clin Vaccine Immunol        ISSN: 1556-679X


  4 in total

1.  Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group.

Authors:  K A Reimann; M R O'Gorman; J Spritzler; C L Wilkening; D E Sabath; K Helm; D E Campbell
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

2.  Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Site Investigators and The NIAID DAIDS New Technologies Evaluation Group.

Authors:  C T Schnizlein-Bick; J Spritzler; C L Wilkening; J K Nicholson; M R O'Gorman
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

3.  Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. Centers for Disease Control and Prevention.

Authors:  Francis F Mandy; Janet K A Nicholson; J Steven McDougal
Journal:  MMWR Recomm Rep       Date:  2003-01-31

4.  Guidelines for using antiretroviral agents among HIV-infected adults and adolescents. Recommendations of the Panel on Clinical Practices for Treatment of HIV.

Authors:  Mark Dybul; Anthony S Fauci; John G Bartlett; Jonathan E Kaplan; Alice K Pau
Journal:  MMWR Recomm Rep       Date:  2002-05-17
  4 in total
  1 in total

Review 1.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.