Literature DB >> 17761252

Covalent immobilization of cholesterol esterase and cholesterol oxidase on polyaniline films for application to cholesterol biosensor.

Suman Singh1, Pratima R Solanki, M K Pandey, B D Malhotra.   

Abstract

Cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) have been covalently immobilized on electrochemically prepared polyaniline (PANI) films. These PANI/ChEt/ChOx enzyme films have been characterized using UV-visible, Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). Electrochemical behavior of these films has been studied using cyclic voltammetry (CV) and amperometric techniques, respectively. The PANI/ChEt/ChOx enzyme films show broad oxidation peak from 0.2 to 0.5 V. These PANI/ChEt/ChOx biosensing electrodes have a response time of about 40s, linearity from 50 to 500 mg/dl of cholesterol oleate concentration. These PANI/ChEt/ChOx films are thermally stable up to 46 degrees C. This polyaniline based cholesterol biosensor has optimum pH in the range of 6.5-7.5, sensitivity as 7.5x10(-4) nA/mg dl and a lifetime of about 6 weeks.

Entities:  

Year:  2005        PMID: 17761252     DOI: 10.1016/j.aca.2005.10.008

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase.

Authors:  C S Pundir; Jagriti Narang; Nidhi Chauhan; Preety Sharma; Renu Sharma
Journal:  Indian J Med Res       Date:  2012-10       Impact factor: 2.375

2.  Development and Practical Application of Glucose Biosensor Based on Dendritic Gold Nanostructures Modified by Conducting Polymers.

Authors:  Natalija German; Anton Popov; Arunas Ramanavicius; Almira Ramanaviciene
Journal:  Biosensors (Basel)       Date:  2022-08-14

Review 3.  Integration of biosensors and drug delivery technologies for early detection and chronic management of illness.

Authors:  Mpho Ngoepe; Yahya E Choonara; Charu Tyagi; Lomas Kumar Tomar; Lisa C du Toit; Pradeep Kumar; Valence M K Ndesendo; Viness Pillay
Journal:  Sensors (Basel)       Date:  2013-06-14       Impact factor: 3.576

4.  pH Sensitivity of Novel PANI/PVB/PS3 Composite Films.

Authors:  Edric Gill; Arousian Arshak; Khalil Arshak; Olga Korostynska
Journal:  Sensors (Basel)       Date:  2007-12-19       Impact factor: 3.576

5.  Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum.

Authors:  Kusum Lata; Vikas Dhull; Vikas Hooda
Journal:  Biochem Res Int       Date:  2016-01-18

6.  Dispersed Conducting Polymer Nanocomposites with Glucose Oxidase and Gold Nanoparticles for the Design of Enzymatic Glucose Biosensors.

Authors:  Natalija German; Almira Ramanaviciene; Arunas Ramanavicius
Journal:  Polymers (Basel)       Date:  2021-06-30       Impact factor: 4.329

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.