Effect of light-curing method and cement activation mode on resin cement knoop hardness.

Rubens Nisie Tango1, Mário Alexandre Coelho Sinhoreti, Américo Bortolazzo Correr, Lourenço Correr-Sobrinho, Guilherme Elias Peçanha Henriques.   

Abstract

PURPOSE: To evaluate the Knoop hardness (KHN) of the resin cement Enforce activated by chemical/physical mode or physical mode solely; light-cured directly or through a 1.5 mm thick ceramic disc (HeraCeram) on shade DD2.
MATERIALS AND METHODS: Light-curing was carried out using a conventional quartz tungsten halogen light (QTH) (XL2500) for 40 seconds at 700 mW/cm(2); light-emitting diodes (LED) (Ultrablue Is) for 40 seconds at 440 mW/cm(2); and Xenon plasma arc (PAC) (Apollo 95E) for 3 seconds at 1600 mW/cm(2). Bovine incisors had their buccal faces flattened and hybridized. A mold was seated on these surfaces and filled with cement. A disc of the acid-etched and silanized veneering material was seated over this set for light-curing. After dry storage (24 hours at 37 degrees C), specimens (n= 10) were sectioned for KHN measurements performed in a microhardness tester (50 gf load for 15 seconds). Data were submitted to ANOVA and Tukey's test (alpha= 0.05).
RESULTS: The highest KHN values were obtained with LED, for both dual-cured and light-cured cement. The lowest KHN value was obtained with light-cured PAC. Light-curing with QTH resulted in hardness values similar to PAC in dual-cured groups.
CONCLUSIONS: Light-curing through HeraCeram can influence resin cement hardness.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17760867     DOI: 10.1111/j.1532-849X.2007.00234.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Authors:  Susana Morimoto; Renata Aló Maluza Zanini; Josete Barbosa Cruz Meira; Carlos Martins Agra; Fernanda Calabró Calheiros; Denis Yudi Nagase
Journal:  Odontology       Date:  2016-01-13       Impact factor: 2.634

2.  Minimum Radiant Exposure and Irradiance for Triggering Adequate Polymerization of a Photo-Polymerized Resin Cement.

Authors:  Qi Li; Hong-Lei Lin; Ming Zheng; Mutlu Ozcan; Hao Yu
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

3.  Influence of energy density of different light sources on Knoop hardness of a dual-cured resin cement.

Authors:  Evandro Piva; Lourenço Correr-Sobrinho; Mario Alexandre Coelho Sinhoreti; Simonides Consani; Flávio Fernando Demarco; John Michael Powers
Journal:  J Appl Oral Sci       Date:  2008 May-Jun       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.