Literature DB >> 17760537

Treatment of titanium dental implants with three piezoelectric ultrasonic scalers: an in vivo study.

Hideyuki Kawashima1, Shuichi Sato, Mamoru Kishida, Hiroaki Yagi, Kazuma Matsumoto, Koichi Ito.   

Abstract

BACKGROUND: Dental implants require regular maintenance. It is crucial that the instrument used for maintenance be able to remove plaque and calculus from the implant surface effectively and efficiently, while causing minimal damage to its circumference. Some ultrasonic scalers may be useful for implant maintenance; however, no clinical study has examined this. This study evaluated the treatment of titanium implants with three piezoelectric scalers in vivo.
METHODS: Fourteen patients underwent implant treatment in which plaque and calculus were removed from the abutment surfaces with ultrasonic scalers. The abutments were treated with scalers with carbon (VS; N = 7), plastic (PS; N = 7), or metallic (ES; N = 7) tips. The abutment surface characteristics were examined after instrumentation using scanning electron microscopy. The amount of plaque remaining and roughness were estimated using a modification of the remaining plaque and calculus score and the modified roughness score, respectively. In addition, the abutment surfaces were imaged with a laser profilometer and a laser scanning electron microscope (SEM).
RESULTS: The remaining plaque and calculus scores did not differ significantly among the VS, PS, and ES groups. VS and PS produced a significantly smoother abutment surface than ES. The laser SEM three-dimensional images also demonstrated that VS and PS produced smooth abutment surfaces, whereas ES resulted in damaged surfaces.
CONCLUSIONS: VS and PS produced clean, smooth abutment surfaces. Piezoelectric scalers with non-metal tips are suitable for use in dental implant maintenance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17760537     DOI: 10.1902/jop.2007.060496

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  5 in total

1.  Surface scratch assessment of titanium implant abutments and cementum following instrumentation with metal curettes.

Authors:  P M Anastassiadis; C Hall; V Marino; P M Bartold
Journal:  Clin Oral Investig       Date:  2014-05-23       Impact factor: 3.573

2.  Biological response of human bone marrow stromal cells to sandblasted titanium nitride-coated implant surfaces.

Authors:  Marco Annunziata; Luigi Guida; Letizia Perillo; Raffaella Aversa; Irene Passaro; Adriana Oliva
Journal:  J Mater Sci Mater Med       Date:  2008-07-16       Impact factor: 3.896

3.  The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing.

Authors:  Minchul Koh; Jun-Beom Park; Yun-Ji Jang; Youngkyung Ko
Journal:  J Periodontal Implant Sci       Date:  2013-12-31       Impact factor: 2.614

4.  Evaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique.

Authors:  Kyung A Chun; Kee-Yeon Kum; Woo-Cheol Lee; Seung-Ho Baek; Hae-Won Choi; Won-Jun Shon
Journal:  BMC Oral Health       Date:  2017-07-11       Impact factor: 2.757

5.  Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study.

Authors:  Nathan Chiang Ping Tan; Catherine M Miller; Elsa Antunes; Dileep Sharma
Journal:  Clin Exp Dent Res       Date:  2021-10-02
  5 in total