Literature DB >> 17729361

High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: comparison of surface coil and volume coil.

Bernd Bittersohl1, Thomas Huang, Erika Schneider, Philip Blazar, Carl Winalski, Philipp Lang, Hiroshi Yoshioka.   

Abstract

PURPOSE: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC).
MATERIALS AND METHODS: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3 T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees , 1 mm slice-thickness, 60 mm field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees , 0.8 mm slice-thickness, 80 mm FOV, 256 x 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded.
RESULTS: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging.
CONCLUSION: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17729361     DOI: 10.1002/jmri.21077

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Imaging of the wrist at 1.5 Tesla using isotropic three-dimensional fast spin echo cube.

Authors:  Kathryn J Stevens; Charles G Wallace; Weitian Chen; Jarrett K Rosenberg; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

Review 2.  [Radiology of the distal radioulnar joint and the ulnocarpal complex].

Authors:  R Schmitt
Journal:  Orthopade       Date:  2018-08       Impact factor: 1.087

Review 3.  High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex.

Authors:  Donald von Borstel; Michael Wang; Kirstin Small; Taiki Nozaki; Hiroshi Yoshioka
Journal:  Magn Reson Med Sci       Date:  2016-08-16       Impact factor: 2.471

4.  Ulnar-sided wrist pain. II. Clinical imaging and treatment.

Authors:  Atsuya Watanabe; Felipe Souza; Peter S Vezeridis; Philip Blazar; Hiroshi Yoshioka
Journal:  Skeletal Radiol       Date:  2009-12-10       Impact factor: 2.199

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.