Literature DB >> 17729091

The hemiplegic arm: interrater reliability and concurrent validity of passive range of motion measurements.

Lex D de Jong1, Alice Nieuwboer, Geert Aufdemkampe.   

Abstract

PURPOSE: To assess whether our measurement protocol using two raters simultaneously yielded reliable passive range of motion measurements of the hemiplegic arm. Additionally, motion ranges were correlated to several factors to examine the concurrent validity of these measurements.
METHOD: Two raters simultaneously assessed five arm motions at baseline, after five and ten weeks in respectively 18, 13 and 12 stroke patients. One tester made the passive movement and the other read the hydrogoniometer. Raters then switched roles.
RESULTS: Intraclass correlation coefficients revealed high agreement between the raters with intraclass correlation coefficients (ICCs) ranging between 0.84 and 0.99. Standard errors of measurement and smallest detectable differences were large for shoulder abduction. Significant correlations were found between shoulder external rotation and flexion. All arm motions correlated negatively to pain at the end range of these motions. Shoulder external rotation and flexion were significantly correlated to the time post stroke. Concurrent validity with Ashworth Scale, Fugl-Meyer Assessment and Barthel Index was limited.
CONCLUSIONS: The current measurement protocol yielded high reliability indices and seems useful for further use. However, standard error of measurement and smallest detectable difference for shoulder abduction were high, implying the necessity to include a large sample size in future studies. Correlations revealed that restricted range of arm motions relate to the time post-stroke and coincide with pain.

Entities:  

Mesh:

Year:  2007        PMID: 17729091     DOI: 10.1080/09638280601056145

Source DB:  PubMed          Journal:  Disabil Rehabil        ISSN: 0963-8288            Impact factor:   3.033


  4 in total

1.  The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report.

Authors:  Morey J Kolber; William J Hanney
Journal:  Int J Sports Phys Ther       Date:  2012-06

2.  Conventional versus neutral positioning in central neurological disease: a multicenter randomized controlled trial.

Authors:  Heidrun Pickenbrock; Vera U Ludwig; Antonia Zapf; Dirk Dressler
Journal:  Dtsch Arztebl Int       Date:  2015-01-16       Impact factor: 5.594

3.  The reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL).

Authors:  Nicholas Lucas; Petra Macaskill; Les Irwig; Robert Moran; Luke Rickards; Robin Turner; Nikolai Bogduk
Journal:  BMC Med Res Methodol       Date:  2013-09-09       Impact factor: 4.615

4.  Injury and training history are associated with glenohumeral internal rotation deficit in youth tennis athletes.

Authors:  Kristin Kalo; Lutz Vogt; Johanna Sieland; Winfried Banzer; Daniel Niederer
Journal:  BMC Musculoskelet Disord       Date:  2020-08-15       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.