Literature DB >> 17728151

Reproducibility of kinematic motion coupling parameters during manual upper cervical axial rotation mobilization: a 3-dimensional in vitro study of the atlanto-axial joint.

E Cattrysse1, S Provyn, P Kool, O Gagey, J P Clarys, P Van Roy.   

Abstract

INTRODUCTION: The reproducibility of the 3-dimensional (3D) kinematic aspects of motion coupling patterns of segmental manual mobilizing techniques is not yet known. This study analyzes the segmental 3D aspects of manual mobilization of the atlanto-axial joint in vitro. METHODS AND MATERIALS: Twenty fresh human cervical specimens were studied in a test-retest situation with two examiners. The specimens were manually mobilized using three different techniques: a regional mobilization technique, a segmental mobilization technique on the atlas with manual fixation of the axis and a segmental mobilization applying a locking technique. Segmental kinematics were registered with a Zebris CMS20 ultrasound-based tracking system. The 3D aspects of motion coupling between main axial rotation and coupled lateral bending were analyzed by six parameters: the range of motion the three motion components, the cross-correlation, the ratio and the shift.
RESULTS: The results indicate stronger intra- than inter-examiner reproducibility. The range of motion of the axial rotation component shows a substantial level of intra- and inter-examiner reproducibility (ICC's 0.67-0.76). The parameters describing the coupling patterns show only moderate to substantial intra-examiner reproducibility for the more experienced of the two examiners (ICC's 0.55-0.68). All other correlations were not significant and no differences could be observed between regional versus segmental techniques.
CONCLUSION: Reproducibility of segmental 3D-aspects of manual mobilization of the atlanto-axial joint in an in vitro situation can differ between examiners. The results of the present study may indicate a possible tendency to higher reproducibility if mobilizations are performed by an examiner with high expertise and experience in applying the specific techniques. Continued investigation including more examiners with different levels of experience and different techniques is necessary to confirm these observations.

Entities:  

Mesh:

Year:  2007        PMID: 17728151     DOI: 10.1016/j.jelekin.2007.06.019

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  3 in total

1.  Reproducibility of global three-dimensional motion during manual atlanto-axial rotation mobilization: an in vitro study.

Authors:  Erik Cattrysse; Steven Provyn; Patrick Kool; Jan Pieter Clarys; Peter Van Roy
Journal:  J Man Manip Ther       Date:  2010-03

2.  Two novel parameters to evaluate the influence of the age and gender on the anatomic relationship of the atlas and axis in children no more than 8 years old: imaging study.

Authors:  Long Wu; Yu Jin; Xiang-Yang Wang; Bi-Dong Fang; Ai-Min Wu; Sheng Wang; Cheng-Long Xie; Zhong-Ke Lin
Journal:  Neuroradiology       Date:  2019-09-11       Impact factor: 2.804

3.  Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer.

Authors:  Kerstin Luedtke; Thomas Schoettker-Königer; Toby Hall; Christine Reimer; Maike Grassold; Petra Hasselhoff-Styhler; Christian Neulinger; Max Obrocki; Philipp Przyhoda; Axel Schäfer
Journal:  BMC Musculoskelet Disord       Date:  2020-08-11       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.