Literature DB >> 17727869

Multiresidue analysis of acidic and polar organic contaminants in water samples by stir-bar sorptive extraction-liquid desorption-gas chromatography-mass spectrometry.

José Benito Quintana1, Rosario Rodil, Soledad Muniategui-Lorenzo, Purificación López-Mahía, Darío Prada-Rodríguez.   

Abstract

The feasibility of stir-bar sorptive extraction (SBSE) followed by liquid desorption in combination with large volume injection (LVI)-in port silylation and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of a broad range of 46 acidic and polar organic pollutants in water samples has been evaluated. The target analytes included phenols (nitrophenols, chlorophenols, bromophenols and alkylphenols), acidic herbicides (phenoxy acids and dicamba) and several pharmaceuticals. Experimental variables affecting derivatisation yield and peak shape as a function of different experimental PTV parameters [initial injection time, pressure and temperature and the ratio solvent volume/N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) volume] were first optimised by an experimental design approach. Subsequently, SBSE conditions, such as pH, ionic strength, agitation speed and extraction time were investigated. After optimisation, the method failed only for the extraction of most polar phenols and some pharmaceuticals, being suitable for the determination of 37 (out of 46) pollutants, with detection limits for these analytes ranging between 1 and 800 ng/L and being lower than 25 ng/L in most cases. Finally, the developed method was validated and applied to the determination of target analytes in various aqueous environmental matrices, including ground, river and wastewater. Acceptable accuracy (70-130%) and precision values (<20%) were obtained for most analytes independently of the matrix, with the exception of some alkylphenols, where an isotopically labelled internal standard would be required in order to correct for matrix effects. Among the drawbacks of the method, carryover was identified as the main problem even though the Twisters were cleaned repeatedly.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17727869     DOI: 10.1016/j.chroma.2007.07.088

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  11 in total

1.  Occurrence and analysis of selected pharmaceutical compounds in soil from Spanish agricultural fields.

Authors:  Ramón Aznar; Consuelo Sánchez-Brunete; Beatriz Albero; José Antonio Rodríguez; José L Tadeo
Journal:  Environ Sci Pollut Res Int       Date:  2013-12-21       Impact factor: 4.223

2.  Hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry for acidic herbicides and metabolites analysis in fresh water.

Authors:  Vincent Fauvelle; Nicolas Mazzella; Soizic Morin; Sylvia Moreira; Brigitte Delest; Hélène Budzinski
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-27       Impact factor: 4.223

3.  A multi-residue method for determination of 70 organic micropollutants in surface waters by solid-phase extraction followed by gas chromatography coupled to tandem mass spectrometry.

Authors:  Evangelia Terzopoulou; Dimitra Voutsa; George Kaklamanos
Journal:  Environ Sci Pollut Res Int       Date:  2014-08-12       Impact factor: 4.223

4.  Determination of nitroaromatic explosive residues in water by stir bar sorptive extraction-gas chromatography-tandem mass spectrometry.

Authors:  Mathieu Galmiche; Adeline Colin; Marie-Christelle Clavos; Christelle Pallez; Christophe Rosin; Xavier Dauchy
Journal:  Anal Bioanal Chem       Date:  2020-10-10       Impact factor: 4.142

5.  Assessment of commercial porous polyethylene frit for extraction of polycyclic aromatic hydrocarbons from water.

Authors:  Xiaoxuan Mou; Xiaoshui Li; Shibin Qin; Huan Li; Shihua Qi
Journal:  Anal Bioanal Chem       Date:  2021-03-24       Impact factor: 4.142

6.  Coupling of solvent-based de-emulsification dispersive liquid-liquid microextraction with high performance liquid chromatography for simultaneous simple and rapid trace monitoring of 2,4-dichlorophenoxyacetic acid and 2-methyl-4-chlorophenoxyacetic acid.

Authors:  Mohammad Behbahani; Fatemeh Najafi; Saman Bagheri; Majid Kalate Bojdi; Parmoon Ghareh Hassanlou; Akbar Bagheri
Journal:  Environ Monit Assess       Date:  2013-12-03       Impact factor: 2.513

7.  Assessment of commercially available polymeric materials for sorptive microextraction of priority and emerging nonpolar organic pollutants in environmental water samples.

Authors:  Laura Blanco-Zubiaguirre; Alejandra Delgado; Oihana Ros; Oscar Posada-Ureta; Asier Vallejo; Ailette Prieto; Maitane Olivares; Nestor Etxebarria
Journal:  Environ Sci Pollut Res Int       Date:  2014-01-15       Impact factor: 4.223

8.  Synthesis of a molecularly imprinted polymer and its application in selective extraction of fenoprofen from wastewater.

Authors:  Zama Emmaculate Mbhele; Somandla Ncube; Lawrence Mzukisi Madikizela
Journal:  Environ Sci Pollut Res Int       Date:  2018-10-31       Impact factor: 4.223

9.  A simple strategy based on fibers coated with surfactant-functionalized multiwalled carbon nanotubes to improve the properties of solid-phase microextraction of phenols in aqueous solution.

Authors:  Xueqing Zhou; Yanli Xie; Zhendong Zhao; Wenyan Fu
Journal:  BMC Chem       Date:  2020-02-19

10.  Evaluation of a Stable Isotope-Based Direct Quantification Method for Dicamba Analysis from Air and Water Using Single-Quadrupole LC-MS.

Authors:  Manoj Ghaste; Nicholas C Hayden; Matthew J Osterholt; Julie Young; Bryan Young; Joshua R Widhalm
Journal:  Molecules       Date:  2020-08-11       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.