Literature DB >> 17727691

Noninvasive peripheral perfusion index as a possible tool for screening for critical left heart obstruction.

A de-Wahl Granelli1, I Ostman-Smith.   

Abstract

AIM: Peripheral perfusion index (PPI) has been suggested as a possible method to detect illness causing circulatory embarrassment. We aimed to establish the normal range of this index in healthy newborns, and compare it with newborns with duct-dependent systemic circulation.
DESIGN: We conducted a case-control study.
SETTING: Our study population comprised 10,000 prospectively recruited newborns from Västra Götaland, Sweden. PATIENTS: A total of 10,000 normal newborns and 9 infants with duct-dependent systemic circulation (left heart obstructive disease [LHOD] group) participated in the study.
METHODS: We conducted single pre- and postductal measurements of PPI with a new generation pulse oximeter (Masimo Radical SET) before discharge from hospital.
RESULTS: PPI values between 1 and 120 h of age show an asymmetrical, non-normal distribution with median PPI value of 1.70 and interquartile range of 1.18-2.50. The 5th percentile = 0.70 and 95th percentile = 4.50. All infants in the LHOD group had either pre- or postductal PPI below the interquartile range, and 5 of 9 (56%) were below the 5th percentile cut-off of 0.70 (p < 0.0001, Fisher's exact test). A PPI value <0.70 gave an odds ratio for LHOD of 23.75 (95% CI 6.36-88.74).
CONCLUSION: PPI values lower than 0.70 may indicate illness and a value <0.50 (1st percentile) indicates definite underperfusion. PPI values might be a useful additional tool for early detection of LHOD.

Entities:  

Mesh:

Year:  2007        PMID: 17727691     DOI: 10.1111/j.1651-2227.2007.00439.x

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  25 in total

1.  Reference values of perfusion indices in hemodynamically stable newborns during the early neonatal period.

Authors:  Nilay Hakan; Dilek Dilli; Aysegul Zenciroglu; Mustafa Aydin; Nurullah Okumus
Journal:  Eur J Pediatr       Date:  2013-12-03       Impact factor: 3.183

2.  Perfusion Index in Very Low Birth Weight Premature Infants During Their First 2 Weeks of Life.

Authors:  Robin B Knobel-Dail; David T Tanaka; Diane Holditch-Davis; John White
Journal:  Biol Res Nurs       Date:  2016-07-26       Impact factor: 2.522

3.  Perfusion index and left ventricular output correlation in healthy term infants.

Authors:  Iuri Corsini; Alessandra Cecchi; Caterina Coviello; Carlo Dani
Journal:  Eur J Pediatr       Date:  2017-05-12       Impact factor: 3.183

4.  False-negative pulse oximetry screening for critical congenital heart disease: the case for parent education.

Authors:  Brandon W Harden; Gerard R Martin; Elizabeth A Bradshaw
Journal:  Pediatr Cardiol       Date:  2012-07-12       Impact factor: 1.655

5.  Oxygen saturation and perfusion index screening in neonates at high altitudes: can PDA be predicted?

Authors:  Kadir Şerafettin Tekgündüz; Merve Bilen; Mustafa Kara; Fuat Laloğlu; Naci Ceviz
Journal:  Eur J Pediatr       Date:  2020-06-05       Impact factor: 3.183

6.  A pilot study to examine maturation of body temperature control in preterm infants.

Authors:  Robin B Knobel; Janet Levy; Laurence Katz; Bob Guenther; Diane Holditch-Davis
Journal:  J Obstet Gynecol Neonatal Nurs       Date:  2013-09-04

7.  Perfusion index variations in clinically and hemodynamically stable preterm newborns in the first week of life.

Authors:  Francesco Cresi; Emanuela Pelle; Roberto Calabrese; Luciana Costa; Daniela Farinasso; Leandra Silvestro
Journal:  Ital J Pediatr       Date:  2010-01-18       Impact factor: 2.638

8.  Interactions among peripheral perfusion, cardiac activity, oxygen saturation, thermal profile and body position in growing low birth weight infants.

Authors:  R Sahni; K F Schulze; K Ohira-Kist; S Kashyap; M M Myers; W P Fifer
Journal:  Acta Paediatr       Date:  2010-01       Impact factor: 2.299

9.  Photoplethysmographic waveform characteristics of newborns with coarctation of the aorta.

Authors:  L Palmeri; G Gradwohl; M Nitzan; E Hoffman; Y Adar; Y Shapir; R Koppel
Journal:  J Perinatol       Date:  2016-09-29       Impact factor: 2.521

10.  The perfusion index derived from a pulse oximeter for predicting low superior vena cava flow in very low birth weight infants.

Authors:  S Takahashi; S Kakiuchi; Y Nanba; K Tsukamoto; T Nakamura; Y Ito
Journal:  J Perinatol       Date:  2009-11-12       Impact factor: 2.521

View more