Literature DB >> 17723620

Sampling and analysis of volatile organics emitted from wastewater treatment plant and drain system of an industrial science park.

Ben-Zen Wu1, Tien-Zhi Feng, Usha Sree, Kong-Hwa Chiu, Jiunn-Guang Lo.   

Abstract

Volatile organic compounds (VOCs) were monitored in the different sections of a wastewater treatment plant (WWTP), the outlet of both the WWTP and rainfall water, and the downstream of the WWTP joining the river in the area or vicinity of an industrial science park located in Hsinchu, Taiwan. Levels of VOCs were determined by collecting air samples over several sampling points and analyzed using gas chromatography. Among VOCs identified in the drainage and effluent system in each season, acetone, isopropanol (IPA) and dimethyl sulfide (DMS) were the major emission species and maximum concentrations were 400.4, 22.8 and 641.2 ppbv, respectively. The ambient air and wastewater sample analysis from neighboring wastewater streams identified pollutants being discharged from unaccounted sources other than the industrial park. According to the 24h semi-continuous monitoring data (27/7/2002-29/7/2002), the total VOC concentration was an average of 93 ppbv (acetone contributed approximately 78%) with a dramatic variation during the day and night. The emission rate of measured VOCs estimated using fixed box model projected an average of 2-4 microg m(-2) h(-1)) during the day and 9-17 microg m(-2) h(-1) during the night. In addition, the isopleth maps show that the acetone and DMS emissions influence adversely the nearby residential area located at less than 100 m downwind from the plant. Eventually, based on this study, an on-line monitoring and alerting system could be built for a long-term performance, and with regular information on the varying pollutants over time construction of a green strategy and creation of a sustainable environment can be achieved.

Entities:  

Year:  2006        PMID: 17723620     DOI: 10.1016/j.aca.2006.03.057

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  13 in total

1.  Comprehensive screening and priority ranking of volatile organic compounds in Daliao River, China.

Authors:  Huilian Ma; Haijun Zhang; Longxing Wang; Jincheng Wang; Jiping Chen
Journal:  Environ Monit Assess       Date:  2014-01-05       Impact factor: 2.513

2.  VOC amounts in ambient areas of a high-technology science park in Taiwan: their reciprocal correlations and impact on inhabitants.

Authors:  Hsin-Wang Liu; Bei-Zen Wu; Hung-Chi Nian; Hsing-Jung Chen; Jiunn-Guang Lo; Kong-Hwa Chiu
Journal:  Environ Sci Pollut Res Int       Date:  2011-07-08       Impact factor: 4.223

3.  Health risk assessment of odors emitted from urban wastewater pump stations in Tianjin, China.

Authors:  Zhi-Guang Niu; Shi-Ying Xu; Qing-Chao Gong
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-11       Impact factor: 4.223

4.  HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge.

Authors:  Urszula Kotowska; Maciej Żalikowski; Valery A Isidorov
Journal:  Environ Monit Assess       Date:  2011-06-18       Impact factor: 2.513

5.  Assessment of indoor airborne contamination in a wastewater treatment plant.

Authors:  Juliana V Teixeira; Sandra Miranda; Ricardo A R Monteiro; Filipe V S Lopes; Joana Madureira; Gabriela V Silva; Nazaré Pestana; Eugénia Pinto; Vítor J P Vilar; Rui A R Boaventura
Journal:  Environ Monit Assess       Date:  2012-02-10       Impact factor: 2.513

6.  Characteristics of malodor pollutants and aromatic VOCs around an urban valley in Korea.

Authors:  Sang-Keun Song; Zang-Ho Shon; Yoo-Keun Kim; Cheol-Hee Kim; Su-Young Yoo; Sang-Hyun Park
Journal:  Environ Monit Assess       Date:  2008-10-11       Impact factor: 2.513

7.  Reduced sulfur compounds in ambient air surrounding an industrial region in Korea.

Authors:  Raktim Pal; Ki-Hyun Kim; Eui-Chan Jeon; Sang-Keun Song; Zang-Ho Shon; Shin-Young Park; Ki-Han Lee; Sun-Jin Hwang; Jong-Min Oh; Youn-Seo Koo
Journal:  Environ Monit Assess       Date:  2008-02-01       Impact factor: 2.513

8.  Emission of volatile organic sulfur compounds from a heavily polluted river in Guangzhou, South China.

Authors:  Yanqing Sheng; Fanzhong Chen; Ying Yu; Xinming Wang; Guoying Sheng; Jiamo Fu; Eddy Y Zeng
Journal:  Environ Monit Assess       Date:  2007-09-12       Impact factor: 2.513

9.  Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.

Authors:  Jacek Gebicki; Hubert Byliński; Jacek Namieśnik
Journal:  Environ Monit Assess       Date:  2015-12-15       Impact factor: 2.513

10.  Electronic Nose Testing Procedure for the Definition of Minimum Performance Requirements for Environmental Odor Monitoring.

Authors:  Lidia Eusebio; Laura Capelli; Selena Sironi
Journal:  Sensors (Basel)       Date:  2016-09-21       Impact factor: 3.576