Literature DB >> 17723452

Evaluation of calix-crown ionophores for selective separation of radio-cesium from acidic nuclear waste solution.

P K Mohapatra1, S A Ansari, A Sarkar, A Bhattacharyya, V K Manchanda.   

Abstract

Extraction of Cs-137 from nitric acid was carried out using nitrobenzene solutions of calix-crowns such as calix[4]arene-bis(crown-6) (CC-A), calix[4]arene-bis(benzo crown-6) (CC-B) and calix[4]arene-bis(napthocrown-6) (CC-C). CC-C was found to be superior extractant for Cs(I) as compared to the other two calix-crown ligands used in the present study. The effect of diluent on the extraction of Cs(I) indicated the trend: nitrobenzene>dichloroethane>chloroform>decanol>>carbon tetrachloride approximately n-hexane approximately toluene. Subsequently, the studies were carried out with nitrobenzene solutions of the calix-crown ligands (mainly CC-C) on the effects of (a) aqueous phase acidity, (b) ligand concentration, and (c) cesium concentration on Cs extraction from nitric acid media. Conditions for quantitative extraction and stripping were optimized and the extracted species conformed to {[CsL]+.[NO3]-.nH2O}. Selectivity studies were carried out using an irradiated natural U target involving tracer amount of fission products activities. Extraction of Cs(I) from a synthetic high level waste solution was also carried out. The promising results obtained in the present studies indicate possible use of the calix-crown ligand for Cs(I) recovery from the acidic high level waste.

Entities:  

Year:  2006        PMID: 17723452     DOI: 10.1016/j.aca.2006.05.006

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Achieving highly efficient and selective cesium extraction using 1,3-di-octyloxycalix[4]arene-crown-6 in n-octanol based solvent system: experimental and DFT investigation.

Authors:  Kankan Patra; Biswajit Sadhu; Arijit Sengupta; C B Patil; R K Mishra; C P Kaushik
Journal:  RSC Adv       Date:  2021-06-16       Impact factor: 3.361

2.  A Reliable Hybrid Adsorbent for Efficient Radioactive Cesium Accumulation from Contaminated Wastewater.

Authors:  Md Rabiul Awual; Tsuyoshi Yaita; Yuji Miyazaki; Daiju Matsumura; Hideaki Shiwaku; Tomitsugu Taguchi
Journal:  Sci Rep       Date:  2016-01-28       Impact factor: 4.379

3.  18-Crown-6 and dibenzo-18-crown-6 assisted extraction of cesium from water into room temperature ionic liquids and its correlation with stability constants for cesium complexes.

Authors:  Andrey G Vendilo; Dmitry I Djigailo; Svetlana V Smirnova; Irina I Torocheshnikova; Konstantin I Popov; Vladimir G Krasovsky; Igor V Pletnev
Journal:  Molecules       Date:  2009-12-02       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.