Literature DB >> 17723393

Self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) nanospheres for fabrication of a mediatorless biosensor.

Shiyi Xu1, Guoli Tu, Bo Peng, Xiaozu Han.   

Abstract

A novel strategy to construct a sensitive mediatorless sensor of H2O2 was described. At first, a cleaned gold electrode was immersed in thiol-functionalized poly(styrene-co-acrylic acid) (St-co-AA) nanosphere latex prepared by emulsifier-free emulsion polymerization St with AA and function with dithioglycol to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups and formed monolayers on the surface of poly(St-co-AA) nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The sensor displayed an excellent electrocatalytical response to reduction of H2O2 without the aid of an electron mediator. The biosensor showed a linear range of 8.0 micromol L(-1)-7.0 mmol L(-1) with a detection limit of 4.0 micromol L(-1). The biosensor retained more than 97.8% of its original activity after 60 days' storage. Moreover, the studied biosensor exhibited good current reproducibility and good fabrication reproducibility.

Entities:  

Year:  2006        PMID: 17723393     DOI: 10.1016/j.aca.2006.04.020

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

Review 2.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

3.  A potentiometric formaldehyde biosensor based on immobilization of alcohol oxidase on acryloxysuccinimide-modified acrylic microspheres.

Authors:  Yew Pei Ling; Lee Yook Heng
Journal:  Sensors (Basel)       Date:  2010-11-05       Impact factor: 3.576

4.  A biosensor for urea from succinimide-modified acrylic microspheres based on reflectance transduction.

Authors:  Alizar Ulianas; Lee Yook Heng; Musa Ahmad
Journal:  Sensors (Basel)       Date:  2011-08-26       Impact factor: 3.576

5.  An electrochemical DNA microbiosensor based on succinimide-modified acrylic microspheres.

Authors:  Alizar Ulianas; Lee Yook Heng; Sharina Abu Hanifah; Tan Ling Ling
Journal:  Sensors (Basel)       Date:  2012-04-27       Impact factor: 3.576

6.  TEMPO-Functionalized Nanoporous Au Nanocomposite for the Electrochemical Detection of H2O2.

Authors:  Dongxiao Wen; Qianrui Liu; Ying Cui; Huaixia Yang; Jinming Kong
Journal:  Int J Anal Chem       Date:  2018-06-10       Impact factor: 1.885

  6 in total