Literature DB >> 17723382

Matrix interference free determination of perchlorate in urine by ion association-ion chromatography-mass spectrometry.

P Kalyani Martinelango1, Gülçin Gümüş, Purnendu K Dasgupta.   

Abstract

Quantitative measurement of perchlorate in biological fluids is of importance to assess its toxicity and to study its effects on the thyroid gland. Whenever possible, urine samples are preferred in toxicologic/epidemiologic studies because sample collection is non-invasive. We present here a pretreatment method for the determination of perchlorate in urine samples that lead to a clean matrix. Urine samples, spiked with isotopically labeled perchlorate, are exposed to UV to destroy/decompose organic molecules and then sequentially treated with an H+-form cation exchange resin to remove protolyzable compounds, with ammonia to raise the pH to 10-11 and finally passed through a mini-column of basic alumina to remove the color and other organic matter. After filtration through a 0.45 microm syringe filter, the sample thus prepared can be directly injected into an ion chromatograph (IC). We use ion association-electrospray ionization-mass spectrometry (ESI-MS) to detect and quantify perchlorate. The proposed sample preparation method leads to excellent limits of detection (LOD's) for perchlorate since there is essentially no dilution of sample and the matrix effects are eliminated. Results of urine samples from both men and women volunteers are reported for perchlorate, as well as for iodide and thiocyanate, which are generally present at much higher concentrations and for which a "dilute and shoot" approach is adequate. The limit of detection (S/N=3) for iodide, thiocyanate and perchlorate by the present method was 0.40, 0.10 and 0.080 microg l(-1), respectively.

Entities:  

Year:  2006        PMID: 17723382     DOI: 10.1016/j.aca.2006.02.022

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  The evaluation and comparison of trigonal and linear tricationic ion-pairing reagents for the detection of anions in positive mode ESI-MS.

Authors:  Molly M Warnke; Zachary S Breitbach; Edra Dodbiba; Eranda Wanigasekara; Xiaotong Zhang; Pritesh Sharma; Daniel W Armstrong
Journal:  J Am Soc Mass Spectrom       Date:  2008-11-27       Impact factor: 3.109

2.  Evaluation of dicationic reagents for their use in detection of anions using positive ion mode ESI-MS via gas phase ion association.

Authors:  Jeffrey W Remsburg; Renee J Soukup-Hein; Jeffrey A Crank; Zachary S Breitbach; Tharanga Payagala; Daniel W Armstrong
Journal:  J Am Soc Mass Spectrom       Date:  2007-11-07       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.