Literature DB >> 17723381

Sample processing method for the determination of perchlorate in milk.

Jason V Dyke1, Andrea B Kirk, P Kalyani Martinelango, Purnendu K Dasgupta.   

Abstract

In recent years, many different water sources and foods have been reported to contain perchlorate. Studies indicate that significant levels of perchlorate are present in both human and dairy milk. The determination of perchlorate in milk is particularly important due to its potential health impact on infants and children. As for many other biological samples, sample preparation is more time consuming than the analysis itself. The concurrent presence of large amounts of fats, proteins, carbohydrates, etc., demands some initial cleanup; otherwise the separation column lifetime and the limit of detection are both greatly compromised. Reported milk processing methods require the addition of chemicals such as ethanol, acetic acid or acetonitrile. Reagent addition is undesirable in trace analysis. We report here an essentially reagent-free sample preparation method for the determination of perchlorate in milk. Milk samples are spiked with isotopically labeled perchlorate and centrifuged to remove lipids. The resulting liquid is placed in a disposable centrifugal ultrafilter device with a molecular weight cutoff of 10 kDa, and centrifuged. Approximately 5-10 ml of clear liquid, ready for analysis, is obtained from a 20 ml milk sample. Both bovine and human milk samples have been successfully processed and analyzed by ion chromatography-mass spectrometry (IC-MS). Standard addition experiments show good recoveries. The repeatability of the analytical result for the same sample in multiple sample cleanup runs ranged from 3 to 6% R.S.D. This processing technique has also been successfully applied for the determination of iodide and thiocyanate in milk.

Entities:  

Year:  2006        PMID: 17723381     DOI: 10.1016/j.aca.2006.02.024

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

Review 1.  Perchlorate, iodine and the thyroid.

Authors:  Angela M Leung; Elizabeth N Pearce; Lewis E Braverman
Journal:  Best Pract Res Clin Endocrinol Metab       Date:  2010-02       Impact factor: 4.690

2.  The evaluation and comparison of trigonal and linear tricationic ion-pairing reagents for the detection of anions in positive mode ESI-MS.

Authors:  Molly M Warnke; Zachary S Breitbach; Edra Dodbiba; Eranda Wanigasekara; Xiaotong Zhang; Pritesh Sharma; Daniel W Armstrong
Journal:  J Am Soc Mass Spectrom       Date:  2008-11-27       Impact factor: 3.109

3.  Evaluation of dicationic reagents for their use in detection of anions using positive ion mode ESI-MS via gas phase ion association.

Authors:  Jeffrey W Remsburg; Renee J Soukup-Hein; Jeffrey A Crank; Zachary S Breitbach; Tharanga Payagala; Daniel W Armstrong
Journal:  J Am Soc Mass Spectrom       Date:  2007-11-07       Impact factor: 3.109

4.  Perchlorate contamination of groundwater from fireworks manufacturing area in South India.

Authors:  Tomohiko Isobe; Shohei P Ogawa; Rina Sugimoto; Karri Ramu; Agus Sudaryanto; Govindan Malarvannan; Gnanasekaran Devanathan; Babu Rajendran Ramaswamy; Natesan Munuswamy; Deavaraj Sankar Ganesh; Jeyaraj Sivakumar; A Sethuraman; V Parthasarathy; Annamalai Subramanian; Jennifer Field; Shinsuke Tanabe
Journal:  Environ Monit Assess       Date:  2012-10-30       Impact factor: 2.513

5.  Determination of perchlorate in infant formula by isotope dilution ion chromatography/tandem mass spectrometry.

Authors:  Z Wang; B P-Y Lau; B Tague; M Sparling; D Forsyth
Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess       Date:  2011-06

6.  Analysis and Exposure Assessment of Perchlorate in Korean Dairy Products with LC-MS/MS.

Authors:  Sung-Hee Oh; Ji-Woo Lee; Pawlas Mandy; Jeong-Eun Oh
Journal:  Environ Health Toxicol       Date:  2011-08-18

7.  Temporal patterns in perchlorate, thiocyanate, and iodide excretion in human milk.

Authors:  Andrea B Kirk; Jason V Dyke; Clyde F Martin; Purnendu K Dasgupta
Journal:  Environ Health Perspect       Date:  2006-11-20       Impact factor: 9.031

8.  Ionic Liquid-Modified Gold Nanoparticle-Based Colorimetric Sensor for Perchlorate Detection via Anion-π Interaction.

Authors:  Büşra Keskin; Ayşem Üzer; Reşat Apak
Journal:  ACS Omega       Date:  2022-08-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.