Literature DB >> 1772301

Ranges of movement at the shoulder complex using an electromagnetic movement sensor.

G R Johnson1, N C Fyfe, M Heward.   

Abstract

There are few published data on the ranges of available motion at the shoulder and no clinical technique for the assessment of three dimensional movement. An electromagnetic movement sensor (Isotrak), which makes three dimensional measurements of shoulder movement and measures the ranges of flexion, extension, abduction in the neutral position, abduction preceded by external rotation, and internal rotation achieved by placing the hand as far up the back as possible, was used to study 16 normal subjects. Intraobserver repeatability was good, and a study of five subjects by two observers showed no significant difference between single measurements made by each. The measured ranges were in broad agreement with published data, though they tended to be smaller. This was attributed to either the bulk of the mounting for the movement sensor or to the immobilisation of the elbow and hence the biceps muscle. Women had greater ranges, except for externally rotated abduction.

Entities:  

Mesh:

Year:  1991        PMID: 1772301      PMCID: PMC1004569          DOI: 10.1136/ard.50.11.824

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  4 in total

1.  The amplitude of forearm and of humeral rotation.

Authors:  N SALTER; H D DARCUS
Journal:  J Anat       Date:  1953-10       Impact factor: 2.610

2.  Normal range of motion of joints in male subjects.

Authors:  D C Boone; S P Azen
Journal:  J Bone Joint Surg Am       Date:  1979-07       Impact factor: 5.284

3.  Normal range of joint movements in shoulder, hip, wrist and thumb with special reference to side: a comparison between two populations.

Authors:  E Allander; O J Björnsson; O Olafsson; N Sigfússon; J Thorsteinsson
Journal:  Int J Epidemiol       Date:  1974-09       Impact factor: 7.196

4.  Reliability of goniometric measurements.

Authors:  D C Boone; S P Azen; C M Lin; C Spence; C Baron; L Lee
Journal:  Phys Ther       Date:  1978-11
  4 in total
  4 in total

1.  Measurement of three dimensional shoulder movement patterns with an electromagnetic tracking device in patients with a frozen shoulder.

Authors:  H M Vermeulen; M Stokdijk; P H C Eilers; C G M Meskers; P M Rozing; T P M Vliet Vlieland
Journal:  Ann Rheum Dis       Date:  2002-02       Impact factor: 19.103

2.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

3.  Rotational strength, range of motion, and function in people with unaffected shoulders from various stages of life.

Authors:  Jean-Sébastien Roy; Joy C Macdermid; Kirsty Usher Boyd; Kenneth J Faber; Darren Drosdowech; George S Athwal
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2009-03-02

4.  Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer.

Authors:  Andrea F de Winter; Monique A M B Heemskerk; Caroline B Terwee; Marielle P Jans; Walter Devillé; Dirk-Jan van Schaardenburg; Rob J P M Scholten; Lex M Bouter
Journal:  BMC Musculoskelet Disord       Date:  2004-06-14       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.