Literature DB >> 17720564

Technical aspects: development, manufacture and installation of a cryo-cooled HTS coil system for high-resolution in-vivo imaging of the mouse at 1.5 T.

Jean-Christophe Ginefri1, Marie Poirier-Quinot, Olivier Girard, Luc Darrasse.   

Abstract

Signal-to-noise ratio improvement is of major importance to achieve microscopic spatial resolution in magnetic resonance experiments. Magnetic resonance imaging of small animals is particularly concerned since it typically requires voxels of less than (100 microm)(3) to observe the small anatomical structures having size reduction by a factor of more than 10 as compared to human being. The signal-to-noise ratio can be increased by working at high static magnetic field strengths, but the biomedical interest of such high-field systems may be limited due to field-dependent contrast mechanisms and severe technological difficulties. An alternative approach that allows working in clinical imaging system is to improve the sensitivity of the radio-frequency receiver coil. This can be done using small cryogenically operated coils made either of copper or high-temperature superconducting material. We report the technological development of cryo-cooled superconducting coils for high-resolution imaging in a whole-body magnetic resonance scanner operating at 1.5 T. The technological background supporting this development is first addressed, including HTS coil design, simulation tools, cryogenic mean description and electrical characterization procedure. To illustrate the performances of superconducting coils for magnetic resonance imaging at intermediate field strength, in-vivo mouse images of various anatomic sites acquired with a 12 mm diameter cryo-cooled superconducting coil are presented.

Entities:  

Mesh:

Year:  2007        PMID: 17720564     DOI: 10.1016/j.ymeth.2007.03.011

Source DB:  PubMed          Journal:  Methods        ISSN: 1046-2023            Impact factor:   3.608


  4 in total

Review 1.  High-field small animal magnetic resonance oncology studies.

Authors:  Louisa Bokacheva; Ellen Ackerstaff; H Carl LeKaye; Kristen Zakian; Jason A Koutcher
Journal:  Phys Med Biol       Date:  2013-12-30       Impact factor: 3.609

2.  Whole body screening using high-temperature superconducting MR volume resonators: mice studies.

Authors:  In-Tsang Lin; Hong-Chang Yang; Jyh-Horng Chen
Journal:  PLoS One       Date:  2012-04-06       Impact factor: 3.240

3.  Enlargement of the field of view and maintenance of a high signal-to-noise ratio using a two-element high-Tc superconducting array in a 3T MRI.

Authors:  In-Tsang Lin; Hong-Chang Yang; Jyh-Horng Chen
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

Review 4.  Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology.

Authors:  Thoralf Niendorf; Andreas Pohlmann; Henning M Reimann; Helmar Waiczies; Eva Peper; Till Huelnhagen; Erdmann Seeliger; Adrian Schreiber; Ralph Kettritz; Klaus Strobel; Min-Chi Ku; Sonia Waiczies
Journal:  Front Pharmacol       Date:  2015-11-12       Impact factor: 5.810

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.