Literature DB >> 17718329

An implementation of synthetic aperture focusing technique in frequency domain.

Tadeusz Stepinski1.   

Abstract

A new implementation of a synthetic aperture focusing technique (SAFT) based on concepts used in synthetic aperture radar and sonar is presented in the paper. The algorithm, based on the convolution model of the imaging system developed in frequency domain, accounts for the beam pattern of the finite-sized transducer used in the synthetic aperture. The 2D fast Fourier transform (FFT) is used for the calculation of a 2D spectrum of the ultrasonic data. The spectrum is then interpolated to convert the polar coordinate system used for the acquisition of ultrasonic signals to the rectangular coordinates used for the presentation of imaging results. After compensating the transducer lobe amplitude profile using a Wiener filter, the transformed spectrum is subjected to the 2D inverse Fourier transform to get the time-domain image again. The algorithm is computationally attractive due to the use of 2D FFT. The performance of the proposed frequency-domain algorithm and the classical time-domain SAFT are compared in the paper using simulated and real ultrasonic data.

Mesh:

Year:  2007        PMID: 17718329     DOI: 10.1109/tuffc.2007.400

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  Stolt's f-k migration for plane wave ultrasound imaging.

Authors:  Damien Garcia; Louis Le Tarnec; Stéphan Muth; Emmanuel Montagnon; Jonathan Porée; Guy Cloutier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

2.  Frequency domain synthetic aperture focusing technique for variable-diameter cylindrical components.

Authors:  Haoran Jin; Eryong Wu; Ye Han; Keji Yang; Jian Chen
Journal:  J Acoust Soc Am       Date:  2017-09       Impact factor: 1.840

3.  Quantitative Frequency-Domain Passive Cavitation Imaging.

Authors:  Kevin J Haworth; Kenneth B Bader; Kyle T Rich; Christy K Holland; T Douglas Mast
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-10-25       Impact factor: 2.725

4.  Short Range Pipe Guided Wave Testing Using SH0 Plane Wave Imaging for Improved Quantification Accuracy.

Authors:  Filip Szlaszynski; Michael J S Lowe; Peter Huthwaite
Journal:  Sensors (Basel)       Date:  2022-04-13       Impact factor: 3.847

5.  A sparse reconstruction algorithm for ultrasonic images in nondestructive testing.

Authors:  Giovanni Alfredo Guarneri; Daniel Rodrigues Pipa; Flávio Neves Junior; Lúcia Valéria Ramos de Arruda; Marcelo Victor Wüst Zibetti
Journal:  Sensors (Basel)       Date:  2015-04-21       Impact factor: 3.576

6.  Quantitative comparison of frequency-domain and delay-and-sum optoacoustic image reconstruction including the effect of coherence factor weighting.

Authors:  Florentin Spadin; Michael Jaeger; Robert Nuster; Pavel Subochev; Martin Frenz
Journal:  Photoacoustics       Date:  2019-12-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.