[Prosthetics of metacarpophalangeal joints].

A Hilker1, R-K Miehlke, K Schmidt.   

Abstract

Only a few of the large number of implants developed during the last decades for replacement of the metacarpophalangeal (MCP) joint have proven to be reliable. The rates of loosening and mechanical failure of almost all types of constrained prostheses are so high that their use cannot be recommended at present. For more than 40 years silicone arthroplasty according to Swanson has been regarded as the gold standard in the prosthetic replacement of the MCP joint. In long-term studies this device provided good pain relief and a lasting correction of preoperative ulnar deviation. The degree of patient satisfaction continues to be high after more than 10 years. With the NeuFlex spacer, a modification of the original Swanson implant, a better range of motion and a reduction of wear-related problems is expected. In this study the results of 130 NeuFlex spacers after a mean time of 3.6 years were examined and 82% of the patients were completely pain free. The mobility of the joints improved from 40 degrees preoperatively to 54 degrees after 3.6 years. Radiologically periprosthetic erosions or osteolyses were seen in approximately 15% of implants. A minimal sinking of the stems developed in 24%, a massive one in 6% and 13% of the spacers were broken. Thus the use of the NeuFlex implant resulted in a better range of motion compared to the Swanson spacer, but the problem of radiological appearance remained unchanged. For unlinked prostheses sufficient soft tissue stability is mandatory as well as wear-resistant surface materials. The pyrocarbon prosthesis according to Beckenbaugh is the only implant for which long-term results are available. In a prospective study we evaluated 28 Ascension pyrocarbon prostheses with a mean follow-up of 4 years. Stability was not found to be a problem. Subjective results were satisfactory, the range of motion remained unchanged, however 46% of prosthesis stems exhibited radiolucent seams, 7 prostheses (25%) were rated as loose and 5 of those had to be replaced by a silicone implant. Use of the implant was abandoned, as it was unreliable regarding bony fixation. There are promising concepts in some new prostheses but independent data are still lacking.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17717677     DOI: 10.1007/s00393-007-0193-1

Source DB:  PubMed          Journal:  Z Rheumatol        ISSN: 0340-1855            Impact factor:   1.372


  41 in total

1.  [Tribologic investigation of a metacarpophalangeal prosthesis].

Authors:  C B Rieker; T Joyce; A Unsworth; F-W Hagena; C Meuli
Journal:  Orthopade       Date:  2003-09       Impact factor: 1.087

2.  [Therapy of rheumatoid destruction of the middle finger metacarpophalangeal joint with a Swanson silastic implant stabilized resection arthroplasty: comparative study of long and intermediate term results with and without implantation of titanium grommets].

Authors:  K Schmidt; K Witt; A Ossowski; R K Miehlke
Journal:  Z Rheumatol       Date:  1997-10       Impact factor: 1.372

3.  Swanson silicone rubber interpositional arthroplasty of the wrist and of the metacarpophalangeal joints in rheumatoid arthritis.

Authors:  B R Simmen; N Gschwend
Journal:  Acta Orthop Belg       Date:  1988       Impact factor: 0.500

4.  Forces in the normal and abnormal hand.

Authors:  K N An; E Y Chao; W P Cooney; R L Linscheid
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

5.  Short-term results of the Ascension pyrolytic carbon metacarpophalangeal joint replacement arthroplasty for osteoarthritis.

Authors:  V A Nuñez; N D Citron
Journal:  Chir Main       Date:  2005 Jun-Aug

6.  Avanta versus Swanson silicone implants in the MCP joint--a prospective, randomized comparison of 30 patients followed for 2 years.

Authors:  K Möller; C Sollerman; M Geijer; P Kopylov; M Tägil
Journal:  J Hand Surg Br       Date:  2005-02

7.  [Synovialectomy of the metacarpophalangeal joints with reconstruction of the radial collateral ligaments -- long-term results in patients suffering from rheumatoid arthritis].

Authors:  K Das Gupta; P Haussmann
Journal:  Handchir Mikrochir Plast Chir       Date:  2005-02       Impact factor: 1.018

8.  [The WEKO finger joint prosthesis].

Authors:  K-D Wessels
Journal:  Handchir Mikrochir Plast Chir       Date:  2005-02       Impact factor: 1.018

9.  A prospective randomized comparison of Sutter and Swanson silastic spacers.

Authors:  P A McArthur; R H Milner
Journal:  J Hand Surg Br       Date:  1998-10

10.  Metacarpophalangeal joint replacement with osseointegrated endoprostheses.

Authors:  C G Hagert; P I Brånemark; T Albrektsson; K G Strid; L Irstam
Journal:  Scand J Plast Reconstr Surg       Date:  1986
View more
  2 in total

Review 1.  [Operative therapy for rheumatoid arthritis of the hand].

Authors:  H-R Springorum; S Winkler; G Maderbacher; J Götz; C Baier; J Grifka; G Heers
Journal:  Z Rheumatol       Date:  2016-02       Impact factor: 1.372

2.  Outcomes of pyrolytic carbon arthroplasty for the proximal interphalangeal joint.

Authors:  Kevin C Chung; Ashwin N Ram; Melissa J Shauver
Journal:  Plast Reconstr Surg       Date:  2009-05       Impact factor: 4.730

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.