Immediate loading of two implants supporting a ball attachment-retained mandibular overdenture: a prospective clinical study.

Riccardo Marzola1, Roberto Scotti, Giovanni Fazi, Gian Pietro Schincaglia.   

Abstract

BACKGROUND: A prospective clinical study was conducted to evaluate clinically and radiographically the performance of two implants immediately loaded supporting a ball attachment-retained mandibular overdenture.
MATERIALS AND METHODS: Seventeen completely edentulous patients were included in the study. Each patient received two implants inserted after a minimal flap reflection and no vestibular extension in order to reduce the postoperative swelling and facilitate immediate prosthesis connection. After implant placement, a mandibular complete denture was connected to the implants using ball attachments of appropriate height according to the depth of the peri-implant tissue. Patients were asked not to remove the denture for 1 week. No limitations to chewing function were given. At implant placement, the maximum value of insertion torque was recorded. Patients were examined at 1, 2, 4, 12, and 52 weeks postsurgery. At postoperative visit, occlusion was checked and the need for any prosthesis maintenance was recorded. The radiographic bone level (RBL) change was measured on periapical radiographs at baseline and 12 months after loading.
RESULTS: After 12 months of loading, no implant failure was reported and the survival rate was 100%. Average RBL change was 0.7 mm +/- 0.5 mm. Of the 17 cases, two had major prosthetic complications and five patients required minor extra maintenance appointments.
CONCLUSIONS: The immediate loading of two implants by means of ball attachment-retained mandibular complete denture may be a predictable treatment option. This clinical approach offers increased stability and comfort, while keeping a high implant success rate.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17716257     DOI: 10.1111/j.1708-8208.2007.00051.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Long-term success of dental implant-supported dentures in postirradiated patients treated for neoplasms of the maxillofacial skeleton: a retrospective study.

Authors:  Yiqun Wu; Wei Huang; Zhiyong Zhang; Zhiyuan Zhang; Duohong Zou
Journal:  Clin Oral Investig       Date:  2016-02-24       Impact factor: 3.573

3.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

Review 4.  Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: A systematic review and meta-analysis.

Authors:  Minoru Sanda; Kenji Fueki; Pranjal Radke Bari; Kazuyoshi Baba
Journal:  Jpn Dent Sci Rev       Date:  2018-10-24

5.  Patient-reported outcomes for the immediate loading of mandibular overdentures supported by two implants soon after implant surgery.

Authors:  Yuriko Komagamine; Manabu Kanazawa; Daisuke Sato; Maiko Iwaki; A Miyayasu; Shunsuke Minakuchi
Journal:  J Dent Sci       Date:  2021-07-20       Impact factor: 2.080

6.  Patient-reported outcomes with immediate-loaded two-implant-supported mandibular overdentures: Results of a 5-year prospective study.

Authors:  Yuriko Komagamine; Manabu Kanazawa; Daisuke Sato; Maiko Iwaki; Anna Miyayasu; Shunsuke Minakuchi
Journal:  J Dent Sci       Date:  2021-06-17       Impact factor: 2.080

7.  Prospective study of treatment outcome of implant retained mandibular overdenture: Two years follow-up.

Authors:  Vimal Arora; Dinesh Kumar; V S Legha; K V Arun Kumar
Journal:  Contemp Clin Dent       Date:  2014-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.