Literature DB >> 17715166

Magnetic resonance-compatible-spirometry: principle, technical evaluation and application.

M Eichinger1, M Puderbach, H-J Smith, R Tetzlaff, A Kopp-Schneider, M Bock, J Biederer, H-U Kauczor.   

Abstract

The aim of this study was to assess the feasibility and accuracy of a novel magnetic resonance-compatible (MRc)-spirometer. The influence of body posture, magnetic resonance (MR)-setting and image acquisition on lung function was evaluated. Dynamic MR imaging (dMRI) was compared with simultaneously measured lung function. The development of the MRc-spirometer was based on a commercial spirometer and evaluated by flow-generator measurements and forced expiratory manoeuvres in 34 healthy nonsmokers (17 females and 17 males, mean age 32.9 yrs). Mean differences between forced expiratory volume in one second (FEV(1)) and forced vital capacity (FVC) were calculated and a sample paired t-test and Bland-Altman plots were generated. A total of 11 subjects underwent different subsequent MRc-spirometric measurements to assess the influence of the components of the MR system on lung function. The mean (95% confidence interval) difference of FEV(1) and FVC between the two systems was 0.004 (-0.04-0.04) L and 0.018 (-0.05-0.09) L, respectively. In the subgroup analysis, an influence of the MR-system on FEV(1) was found. FEV(1) correlated well with the dMRI measurement of the apico-diaphragmatic distance-change after the first second of forced expiration (r = 0.72). In conclusion, magnetic resonance-compatible-spirometry is feasible, reliable and safe. The magnetic resonance-setting only has a small influence on simultaneously measured forced expiratory volume in one second. Dynamic magnetic resonance imaging measurements correlate well with simultaneously acquired lung function parameters.

Mesh:

Year:  2007        PMID: 17715166     DOI: 10.1183/09031936.00040607

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  5 in total

Review 1.  [Magnetic resonance imaging of respiratory movement and lung function].

Authors:  R Tetzlaff; M Eichinger
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

Review 2.  Can lung MR replace lung CT?

Authors:  Michael Puderbach; Hans-Ulrich Kauczor
Journal:  Pediatr Radiol       Date:  2008-06

3.  Dynamic perfluorinated gas MRI reveals abnormal ventilation despite normal FEV1 in cystic fibrosis.

Authors:  Jennifer L Goralski; Sang Hun Chung; Tyler M Glass; Agathe S Ceppe; Esther O Akinnagbe-Zusterzeel; Aaron T Trimble; Richard C Boucher; Brian J Soher; H Cecil Charles; Scott H Donaldson; Yueh Z Lee
Journal:  JCI Insight       Date:  2020-01-30

4.  Human upper-airway respiratory airflow: In vivo comparison of computational fluid dynamics simulations and hyperpolarized 129Xe phase contrast MRI velocimetry.

Authors:  Qiwei Xiao; Neil J Stewart; Matthew M Willmering; Chamindu C Gunatilaka; Robert P Thomen; Andreas Schuh; Guruprasad Krishnamoorthy; Hui Wang; Raouf S Amin; Charles L Dumoulin; Jason C Woods; Alister J Bates
Journal:  PLoS One       Date:  2021-08-19       Impact factor: 3.752

5.  First MRI application of an active breathing coordinator.

Authors:  E Kaza; R Symonds-Tayler; D J Collins; F McDonald; H A McNair; E Scurr; D-M Koh; M O Leach
Journal:  Phys Med Biol       Date:  2015-01-29       Impact factor: 3.609

  5 in total