Channel and substrate zone two-dimensional resolution for chemiluminescent multiplex immunoassay.

Zhifeng Fu1, Zhanjun Yang, Jinhai Tang, Hong Liu, Feng Yan, Huangxian Ju.   

Abstract

A two-dimensional resolution system of channels and substrate zones was proposed for multiplex immunoassay performed with a designed multichannel chemiluminescent (CL) detection device coupled with a single photomultiplier. Using carcinoma antigen 125 (CA 125), carcinoma antigen 153 (CA 153), carcinoma antigen 199 (CA 199), and carcinoembryonic antigen (CEA) as two couples of model analytes, two couples of capture antibodies were immobilized in two channels, respectively. With a sandwich format, the CL substrates for alkaline phosphatase and horseradish peroxidase were delivered into the channels sequentially to perform a multiplex immunoassay after the sample and tracer antibodies were introduced into the channels for on-line incubation. CA 125, CA 153, CA 199, and CEA could be assayed in the ranges of 0.50-80, 2.0-100, and 5.0-150 U/mL and 1.0-70 ng/mL with limits of detection of 0.15, 0.80, and 2.0 U/mL and 0.65 ng/mL at 3sigma, respectively. The whole assay process including regeneration of the device could be completed in 37 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. This technique provides a new strategy for a simple, automated, and near-simultaneous multianalyte immunoassay.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17713968     DOI: 10.1021/ac0711900

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Lateral flow assay for carbohydrate antigen 19-9 in whole blood by using magnetized carbon nanotubes.

Authors:  Yan Huang; Yongqiang Wen; Kwaku Baryeh; Sunitha Takalkar; Michelle Lund; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2017-08-25       Impact factor: 5.833

2.  Efficient label-free chemiluminescent immunosensor based on dual functional cupric oxide nanorods as peroxidase mimics.

Authors:  Juan Li; Yue Cao; Samuel S Hinman; Kristy S McKeating; Yiwen Guan; Xiaoya Hu; Quan Cheng; Zhanjun Yang
Journal:  Biosens Bioelectron       Date:  2017-09-09       Impact factor: 10.618

3.  Multiplex detection of B-type natriuretic peptide, cardiac troponin I and C-reactive protein with photonic suspension array.

Authors:  Wenbin Lu; Cong Fu; Yong Chen; Jun Lu; Yuyu Yao; Chengxing Shen; Zhongze Gu
Journal:  PLoS One       Date:  2012-07-27       Impact factor: 3.240