Literature DB >> 17713350

Three-dimensional echocardiographic analysis of left ventricular function during hemodialysis.

Boudewijn J Krenning1, Marco M Voormolen, Marcel L Geleijnse, Anton F W van der Steen, Folkert J ten Cate, Eric H Y Ie, Jos R T C Roelandt.   

Abstract

BACKGROUND: The effects of hemodialysis (HD) on left ventricular (LV) function have been studied by various echocardiographic techniques (M-mode, 2D echocardiography). These studies are hampered by a low accuracy of measurements because of geometric assumptions regarding LV shape. Three-dimensional echocardiography (3DE) overcomes this limitation.
METHODS: We tested the feasibility of 3DE assessment of LV function during HD. Conventional biplane Simpson rule (BSR) and single plane area length method (SPM) for LV function analysis were used as a reference.
RESULTS: 12 HD patients were studied and in 10 (83%) a total of 80 3D datasets were acquired. In 3 patients, one dataset (4%) was of insufficient quality and excluded from analysis. Correlation between SPM, BSR and 3DE for calculation of end-diastolic (EDV, r = 0.89 and r = 0.92, respectively), end-systolic volume (ESV, r = 0.92 and r = 0.93, respectively) and for ejection fraction (EF, r = 0.90 and r = 0.88, respectively) was moderate. Limits-of-agreement results for EDV and ESV were poor with confidence intervals larger than 30 ml. Both 2DE methods underestimated end-diastolic and end-systolic volume, while overestimating ejection fraction.
CONCLUSION: 3DE is feasible for image acquisition during HD, which opens the possibility for accurate and reproducible measurement of LV function during HD. This may improve the assessment of the acute effect of HD on LV performance, and guide therapeutic strategies aimed at preventing intradialytic hypotension. (c) 2007 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2007        PMID: 17713350     DOI: 10.1159/000107553

Source DB:  PubMed          Journal:  Nephron Clin Pract        ISSN: 1660-2110


  5 in total

Review 1.  Cardiac imaging in patients with chronic kidney disease.

Authors:  Diana Y Y Chiu; Darren Green; Nik Abidin; Smeeta Sinha; Philip A Kalra
Journal:  Nat Rev Nephrol       Date:  2015-01-06       Impact factor: 28.314

2.  Left Ventricular Mass Assessment by 1- and 2-Dimensional Echocardiographic Methods in Hemodialysis Patients: Changes in Left Ventricular Volume Using Echocardiography Before and After a Hemodialysis Session.

Authors:  Charlotte Burup Kristensen; Frank Steensgaard-Hansen; Katrine Aagaard Myhr; Niels Jørgen Løkkegaard; Stine Høyer Finsen; Christian Hassager; Rasmus Møgelvang
Journal:  Kidney Med       Date:  2020-08-06

3.  Three-Dimensional Imaging of a Central Venous Dialysis Catheter Related Infected Thrombus.

Authors:  Diana Yuan Yng Chiu; Darren Green; Philip A Kalra; Nik Abidin
Journal:  Case Rep Nephrol       Date:  2015-11-24

Review 4.  Cardiac Imaging in Heart Failure with Comorbidities.

Authors:  Chiew Wong; Sylvia Chen; Pupalan Iyngkaran
Journal:  Curr Cardiol Rev       Date:  2017

5.  The impact of preload on 3-dimensional deformation parameters: principal strain, twist and torsion.

Authors:  Hyo-Suk Ahn; Yong-Kyun Kim; Ho Chul Song; Euy Jin Choi; Gee-Hee Kim; Jung Sun Cho; Sang-Hyun Ihm; Hee-Yeol Kim; Chan Seok Park; Ho-Joong Youn
Journal:  Cardiovasc Ultrasound       Date:  2017-09-12       Impact factor: 2.062

  5 in total