Literature DB >> 17711969

The pulmonary artery catheter in anesthesia practice in 2007: an historical overview with emphasis on the past 6 years.

Andrew B Leibowitz1, John M Oropello.   

Abstract

The pulmonary artery catheter has been widely used in anesthesiology and critical care medicine. Until recently, only retrospective or relatively weak prospective studies examining its effect on outcome had been performed. Over the past 6 years, however, a number of well-designed prospective trials and statistically sound retrospective studies have been completed. All of these show no benefit and some even reveal a potential for increased morbidity. Reasons for this device's inability to improve outcome are numerous, including wrong patient selection and misinterpretation, but the most impressive and convincing evidence is that filling pressures measured from the catheter, particularly the pulmonary artery "wedge" pressure, have no physiologic value. The wedge pressure has been shown to not correlate with other accepted methods of determining left ventricular filling or volume or intravascular volume and also does not help to generate cardiac function curves. Therefore, knowledge of it may actually lead to incorrect management more frequently than not.

Entities:  

Mesh:

Year:  2007        PMID: 17711969     DOI: 10.1177/1089253207306102

Source DB:  PubMed          Journal:  Semin Cardiothorac Vasc Anesth        ISSN: 1089-2532


  5 in total

Review 1.  Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable.

Authors:  Mik Wetterslev; Hasse Møller-Sørensen; Rasmus Rothmann Johansen; Anders Perner
Journal:  Intensive Care Med       Date:  2016-03-01       Impact factor: 17.440

2.  Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients.

Authors:  Ashwath Sundaresan; J Geoffrey Chase; Christopher E Hann; Geoffrey M Shaw
Journal:  Biomed Eng Online       Date:  2010-11-25       Impact factor: 2.819

3.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

Review 4.  [Perioperative fluid management in major abdominal surgery].

Authors:  M von der Forst; S Weiterer; M Dietrich; M Loos; C Lichtenstern; M A Weigand; B H Siegler
Journal:  Anaesthesist       Date:  2021-02       Impact factor: 1.041

5.  Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients.

Authors:  John F Stover; Reto Stocker; Renato Lenherr; Thomas A Neff; Silvia R Cottini; Bernhard Zoller; Markus Béchir
Journal:  BMC Anesthesiol       Date:  2009-10-12       Impact factor: 2.217

  5 in total