Abstract

It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17710285     DOI: 10.1590/s1806-83242007000300004

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  Pea protein provides a promising matrix for microencapsulating iron.

Authors:  Luciana Linhares de Azevedo Bittencourt; Cristiana Pedrosa; Valéria Pereira de Sousa; Anna Paola Trindade Pierucci; Marta Citelli
Journal:  Plant Foods Hum Nutr       Date:  2013-12       Impact factor: 3.921

2.  The Influence of Saliva pH on the Fracture Resistance of Three Complete Denture Base Acrylic Resins.

Authors:  Juliana de Sá; Francisca Vieira; Carlos Manuel Aroso; Mónica Cardoso; José Manuel Mendes; António Sérgio Silva
Journal:  Int J Dent       Date:  2020-11-01

3.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

4.  Sphere-plane methodology to evaluate the wear of titanium of dental implants: a research proposal.

Authors:  Teresa Almeida Mendes; João Caramês; Luís Pires Lopes; Amílcar Lopes Ramalho
Journal:  BMC Res Notes       Date:  2018-07-31

5.  Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study.

Authors:  Carlos Aroso; Antonio Sergio Silva; Raul Ustrell; Jose Manuel Mendes; Ana Cristina Braga; Esther Berastegui; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.