Randomized trial of screen-film versus full-field digital mammography with soft-copy reading in population-based screening program: follow-up and final results of Oslo II study.

Per Skaane1, Solveig Hofvind, Arnulf Skjennald.   

Abstract

PURPOSE: To prospectively compare performance indicators at screen-film mammography (SFM) and full-field digital mammography (FFDM) in a population-based screening program.
MATERIALS AND METHODS: The regional ethics committee approved the study; informed consent was obtained from patients. Women aged 45-69 years were assigned to undergo SFM (n=16 985) or FFDM (n=6944). Two-view mammograms were interpreted by using independent double reading and a five-point rating scale for probability of cancer. Positive scores were discussed at consensus meetings before decision for recall. The group was followed up for 1.5 years (women aged 45-49 years) and 2.0 years (women aged 50-69 years) to include subsequent cancers with positive scores at baseline interpretation and to estimate interval cancer rate. Recall rates, cancer detection, positive predictive values (PPVs), sensitivity, specificity, tumor characteristics, and discordant interpretations of cancers were compared.
RESULTS: Recall rate was 4.2% at FFDM and 2.5% at SFM (P<.001). Cancer detection rate was 0.59% at FFDM and 0.38% at SFM (P=.02). There was no significant difference in PPVs. Median size of screening-detected invasive cancers was 14 mm at FFDM and 13 mm at SFM. Including cancers dismissed at consensus meetings, overall true-positive rate at baseline reading was 0.63% at FFDM and 0.43% at SFM (P=.04). Sensitivity was 77.4% at FFDM and 61.5% at SFM (P=.07); specificity was 96.5% and 97.9%, respectively (P<.005). Interval cancer rate was 17.4 at FFDM and 23.6 at SFM. The proportion of cancers with discordant double readings was comparable at FFDM and SFM.
CONCLUSION: FFDM resulted in a significantly higher cancer detection rate than did SFM. The PPVs were comparable for the two imaging modalities. Copyright (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17709826     DOI: 10.1148/radiol.2443061478

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  58 in total

1.  Comparison of the clinical performance of three digital mammography systems in a breast cancer screening programme.

Authors:  E Keavey; N Phelan; A M O'Connell; F Flanagan; A O'Doherty; A Larke; A M Connors
Journal:  Br J Radiol       Date:  2011-11-17       Impact factor: 3.039

Review 2.  [Physical aspects of different tomosynthesis systems].

Authors:  F Semturs; E Sturm; R Gruber; T H Helbich
Journal:  Radiologe       Date:  2010-11       Impact factor: 0.635

3.  Impact of the Introduction of Digital Mammography in an Organized Screening Program on the Recall and Detection Rate.

Authors:  Cinzia Campari; Paolo Giorgi Rossi; Carlo Alberto Mori; Sara Ravaioli; Andrea Nitrosi; Rita Vacondio; Pamela Mancuso; Antonella Cattani; Pierpaolo Pattacini
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

4.  Mammographic performance in a population-based screening program: before, during, and after the transition from screen-film to full-field digital mammography.

Authors:  Solveig Hofvind; Per Skaane; Joann G Elmore; Sofie Sebuødegård; Solveig Roth Hoff; Christoph I Lee
Journal:  Radiology       Date:  2014-04-01       Impact factor: 11.105

5.  Comparative effectiveness of digital versus film-screen mammography in community practice in the United States: a cohort study.

Authors:  Karla Kerlikowske; Rebecca A Hubbard; Diana L Miglioretti; Berta M Geller; Bonnie C Yankaskas; Constance D Lehman; Stephen H Taplin; Edward A Sickles
Journal:  Ann Intern Med       Date:  2011-10-18       Impact factor: 25.391

6.  Bias in estimating accuracy of a binary screening test with differential disease verification.

Authors:  Todd A Alonzo; John T Brinton; Brandy M Ringham; Deborah H Glueck
Journal:  Stat Med       Date:  2011-04-15       Impact factor: 2.373

7.  Direct Regularization From Co-Registered Contrast MRI Improves Image Quality of MRI-Guided Near-Infrared Spectral Tomography of Breast Lesions.

Authors:  Limin Zhang; Shudong Jiang; Yan Zhao; Jinchao Feng; Brian W Pogue; Keith D Paulsen
Journal:  IEEE Trans Med Imaging       Date:  2018-05       Impact factor: 10.048

Review 8.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

9.  Cancelled stereotactic biopsy of calcifications not seen using the stereotactic technique: do we still need to biopsy?

Authors:  Sandra B Brennan; Donna D'Alessio; Laura Liberman; Dilip Giri; Edi Brogi; Elizabeth A Morris
Journal:  Eur Radiol       Date:  2013-11-12       Impact factor: 5.315

10.  Adaptable near-infrared spectroscopy fiber array for improved coupling to different breast sizes during clinical MRI.

Authors:  Michael A Mastanduno; Fadi El-Ghussein; Shudong Jiang; Roberta Diflorio-Alexander; Xu Junqing; Yin Hong; Brian W Pogue; Keith D Paulsen
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.