The CCC macro is presented for computation of the concordance correlation coefficient (CCC), a common measure of reproducibility. The macro has been produced in both SAS and R, and a detailed presentation of the macro input and output for the SAS program is included. The macro provides estimation of three versions of the CCC, as presented by Lin [L.I.-K. Lin, A concordance correlation coefficient to evaluate reproducibility, Biometrics 45 (1989) 255-268], Barnhart et al. [H.X. Barnhart, J.L. Haber, J.L. Song, Overall concordance correlation coefficient for evaluating agreement among multiple observers, Biometrics 58 (2002) 1020-1027], and Williamson et al. [J.M. Williamson, S.B. Crawford, H.M. Lin, Resampling dependent concordance correlation coefficients, J. Biopharm. Stat. 17 (2007) 685-696]. It also provides bootstrap confidence intervals for the CCC, as well as for the difference in CCCs for both independent and dependent samples. The macro is designed for balanced data only. Detailed explanation of the involved computations and macro variable definitions are provided in the text. Two biomedical examples are included to illustrate that the macro can be easily implemented.

Mesh:

Year:  2007        PMID: 17709153     DOI: 10.1016/j.cmpb.2007.07.003

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  22 in total

1.  Corpus callosum length by gestational age as evaluated by fetal MR imaging.

Authors:  J H Harreld; R Bhore; D P Chason; D M Twickler
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-23       Impact factor: 3.825

2.  Concordance of MEG and fMRI patterns in adolescents during verb generation.

Authors:  Yingying Wang; Scott K Holland; Jennifer Vannest
Journal:  Brain Res       Date:  2012-02-09       Impact factor: 3.252

3.  Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring.

Authors:  Jason Ostenson; Ryan K Robison; Nicholas R Zwart; E Brian Welch
Journal:  Magn Reson Imaging       Date:  2017-07-08       Impact factor: 2.546

4.  Diagnostic Performance of Creatinine-Based Equations for Estimating Glomerular Filtration Rate in Adults 65 Years and Older.

Authors:  Luciano da Silva Selistre; Dener L Rech; Vandréa de Souza; Jean Iwaz; Sandrine Lemoine; Laurence Dubourg
Journal:  JAMA Intern Med       Date:  2019-06-01       Impact factor: 21.873

5.  Pulmonary symptoms measured by the national institutes of health lung score predict overall survival, nonrelapse mortality, and patient-reported outcomes in chronic graft-versus-host disease.

Authors:  Jeanne Palmer; Kirsten Williams; Yoshihiro Inamoto; Xiaoyu Chai; Paul J Martin; Linus Santo Tomas; Corey Cutler; Daniel Weisdorf; Brenda F Kurland; Paul A Carpenter; Joseph Pidala; Steven Z Pavletic; William Wood; David Jacobsohn; Sally Arai; Mukta Arora; Madan Jagasia; Georgia B Vogelsang; Stephanie J Lee
Journal:  Biol Blood Marrow Transplant       Date:  2013-12-04       Impact factor: 5.742

6.  MR fingerprinting with simultaneous T1, T2, and fat signal fraction estimation with integrated B0 correction reduces bias in water T1 and T2 estimates.

Authors:  Jason Ostenson; Bruce M Damon; E Brian Welch
Journal:  Magn Reson Imaging       Date:  2019-03-23       Impact factor: 2.546

7.  Diffusion-Weighted Breast Magnetic Resonance Imaging: A Semiautomated Voxel Selection Technique Improves Interreader Reproducibility of Apparent Diffusion Coefficient Measurements.

Authors:  Habib Rahbar; Brenda F Kurland; Matthew L Olson; Averi E Kitsch; John R Scheel; Xiaoyu Chai; Joshua Usoro; Constance D Lehman; Savannah C Partridge
Journal:  J Comput Assist Tomogr       Date:  2016 May-Jun       Impact factor: 1.826

8.  Evaluation of the Mercy TAPE: performance against the standard for pediatric weight estimation.

Authors:  Susan M Abdel-Rahman; Ian M Paul; Laura P James; Andrew Lewandowski
Journal:  Ann Emerg Med       Date:  2013-04-17       Impact factor: 5.721

Review 9.  Quantitative imaging biomarkers: a review of statistical methods for technical performance assessment.

Authors:  David L Raunig; Lisa M McShane; Gene Pennello; Constantine Gatsonis; Paul L Carson; James T Voyvodic; Richard L Wahl; Brenda F Kurland; Adam J Schwarz; Mithat Gönen; Gudrun Zahlmann; Marina V Kondratovich; Kevin O'Donnell; Nicholas Petrick; Patricia E Cole; Brian Garra; Daniel C Sullivan
Journal:  Stat Methods Med Res       Date:  2014-06-11       Impact factor: 3.021

10.  Test-Retest Reproducibility of 18F-FDG PET/CT Uptake in Cancer Patients Within a Qualified and Calibrated Local Network.

Authors:  Brenda F Kurland; Lanell M Peterson; Andrew T Shields; Jean H Lee; Darrin W Byrd; Alena Novakova-Jiresova; Mark Muzi; Jennifer M Specht; David A Mankoff; Hannah M Linden; Paul E Kinahan
Journal:  J Nucl Med       Date:  2018-10-25       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.