Literature DB >> 17707693

A light load eccentric exercise confers protection against a subsequent bout of more demanding eccentric exercise.

Andrew P Lavender1, Kazunori Nosaka.   

Abstract

This study investigated the hypothesis that a light eccentric exercise (ECC) that does not induce a loss of muscle function and delayed onset muscle soreness would confer a protective effect against a more strenuous ECC. Eighteen young men were randomly placed into two groups: 10-40% (n=9) and 40% (n=9). Subjects in the 10-40% group performed ECC of the elbow flexors (six sets of five reps) using a dumbbell set at 10% of maximal isometric strength (MVC) at an elbow joint angle of 90 degrees , followed 2 days later by ECC using a dumbbell weight of 40% MVC. Subjects in the 40% group performed the 40% ECC only. Changes in MVC, range of motion (ROM), upper arm circumference (CIR), plasma creatine kinase (CK) activity and muscle soreness before, immediately after, 1-5 and 7 days following the 40% ECC were compared between groups by a two-way repeated measures ANOVA. No significant changes in any of the criterion measures were found immediately and 1-2 days after the 10% ECC. Following the 40% ECC, the 10-40% group showed significantly (P<0.05) smaller decreases in MVC and ROM, and smaller increases in muscle soreness compared with the 40% group, but no significant differences between groups were evident for CIR and plasma CK activity. These results suggest that the 10% ECC induced some protection against a subsequent bout of 40% ECC performed 2 days later. It appears that the light eccentric exercise preconditioned the muscles for exposure to the subsequent damaging eccentric exercise bout.

Entities:  

Mesh:

Year:  2007        PMID: 17707693     DOI: 10.1016/j.jsams.2007.03.005

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  30 in total

1.  Effects of set-repetition configuration in eccentric exercise on muscle damage and the repeated bout effect.

Authors:  R Chan; M Newton; K Nosaka
Journal:  Eur J Appl Physiol       Date:  2011-11-19       Impact factor: 3.078

2.  Effects of low-intensity concentric and eccentric exercise combined with blood flow restriction on indices of exercise-induced muscle damage.

Authors:  Robert S Thiebaud; Tomohiro Yasuda; Jeremy P Loenneke; Takashi Abe
Journal:  Interv Med Appl Sci       Date:  2013-07-04

3.  Comparison between old and young men for responses to fast velocity maximal lengthening contractions of the elbow flexors.

Authors:  Dale W Chapman; M Newton; M R McGuigan; K Nosaka
Journal:  Eur J Appl Physiol       Date:  2008-06-27       Impact factor: 3.078

Review 4.  Muscle damage induced by electrical stimulation.

Authors:  Kazunori Nosaka; Abdulaziz Aldayel; Marc Jubeau; Trevor C Chen
Journal:  Eur J Appl Physiol       Date:  2011-08-03       Impact factor: 3.078

5.  Does a bout of strength training affect 2,000 m rowing ergometer performance and rowing-specific maximal power 24 h later?

Authors:  Thomas I Gee; Duncan N French; Glyn Howatson; Stephen J Payton; Nicolas J Berger; Kevin G Thompson
Journal:  Eur J Appl Physiol       Date:  2011-03-10       Impact factor: 3.078

6.  Comparison in muscle damage between maximal voluntary and electrically evoked isometric contractions of the elbow flexors.

Authors:  Marc Jubeau; Makii Muthalib; Guillaume Y Millet; Nicola A Maffiuletti; Kazunori Nosaka
Journal:  Eur J Appl Physiol       Date:  2011-05-15       Impact factor: 3.078

7.  The effect of eccentric exercise with blood flow restriction on neuromuscular activation, microvascular oxygenation, and the repeated bout effect.

Authors:  Jakob D Lauver; Trent E Cayot; Timothy Rotarius; Barry W Scheuermann
Journal:  Eur J Appl Physiol       Date:  2017-03-21       Impact factor: 3.078

8.  Low-intensity eccentric contractions attenuate muscle damage induced by subsequent maximal eccentric exercise of the knee extensors in the elderly.

Authors:  Trevor C Chen; Wei-Chin Tseng; Guan-Ling Huang; Hsin-Lian Chen; Kou-Wei Tseng; Kazunori Nosaka
Journal:  Eur J Appl Physiol       Date:  2012-10-12       Impact factor: 3.078

9.  Symptomatic and functional responses to concentric-eccentric isokinetic versus eccentric-only isotonic exercise.

Authors:  Jeffrey J Parr; Joshua F Yarrow; Carolyn M Garbo; Paul A Borsa
Journal:  J Athl Train       Date:  2009 Sep-Oct       Impact factor: 2.860

10.  Effects of age and glutathione levels on oxidative stress in rats after chronic exposure to stretch-shortening contractions.

Authors:  Melinda S Hollander; Brent A Baker; James Ensey; Michael L Kashon; Robert G Cutlip
Journal:  Eur J Appl Physiol       Date:  2009-10-31       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.