Literature DB >> 17706656

Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration.

P W de Bruin1, B L Kaptein, B C Stoel, J H C Reiber, P M Rozing, E R Valstar.   

Abstract

Image-based Roentgen stereophotogrammetric analysis (IBRSA) integrates 2D-3D image registration and conventional RSA. Instead of radiopaque RSA bone markers, IBRSA uses 3D CT data, from which digitally reconstructed radiographs (DRRs) are generated. Using 2D-3D image registration, the 3D pose of the CT is iteratively adjusted such that the generated DRRs resemble the 2D RSA images as closely as possible, according to an image matching metric. Effectively, by registering all 2D follow-up moments to the same 3D CT, the CT volume functions as common ground. In two experiments, using RSA and using a micromanipulator as gold standard, IBRSA has been validated on cadaveric and sawbone scapula radiographs, and good matching results have been achieved. The accuracy was: |mu |< 0.083 mm for translations and |mu| < 0.023 degrees for rotations. The precision sigma in x-, y-, and z-direction was 0.090, 0.077, and 0.220 mm for translations and 0.155 degrees , 0.243 degrees , and 0.074 degrees for rotations. Our results show that the accuracy and precision of in vitro IBRSA, performed under ideal laboratory conditions, are lower than in vitro standard RSA but higher than in vivo standard RSA. Because IBRSA does not require radiopaque markers, it adds functionality to the RSA method by opening new directions and possibilities for research, such as dynamic analyses using fluoroscopy on subjects without markers and computer navigation applications.

Entities:  

Mesh:

Year:  2007        PMID: 17706656     DOI: 10.1016/j.jbiomech.2007.07.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries.

Authors:  Hooman Esfandiari; Carolyn Anglin; Pierre Guy; John Street; Simon Weidert; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-10       Impact factor: 2.924

2.  Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures.

Authors:  Albert Christersson; Johan Nysjö; Lars Berglund; Filip Malmberg; Ida-Maria Sintorn; Ingela Nyström; Sune Larsson
Journal:  Skeletal Radiol       Date:  2016-02-27       Impact factor: 2.199

3.  Low-field magnetic resonance imaging offers potential for measuring tibial component migration.

Authors:  F F Schröder; N J J Verdonschot; B Ten Haken; A Peters; A J H Vochteloo; D F M Pakvis; R Huis In't Veld
Journal:  J Exp Orthop       Date:  2018-01-12

4.  Marker free model-based radiostereometric analysis for evaluation of hip joint kinematics: A validation study.

Authors:  L Hansen; S De Raedt; P B Jørgensen; B Mygind-Klavsen; B Kaptein; M Stilling
Journal:  Bone Joint Res       Date:  2018-07-07       Impact factor: 5.853

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.