Literature DB >> 17703975

Precision and sensitivity optimization of quantitative measurements in solid state NMR.

Fabio Ziarelli1, Stéphane Viel, Stéphanie Sanchez, David Cross, Stefano Caldarelli.   

Abstract

This work presents a methodology for optimizing the precision, accuracy and sensitivity of quantitative solid state NMR measurements based on the external reference method. It is shown that the sample must be exclusively located within and completely span the coil region where the NMR response is directly proportional to the sample amount. We describe two methods to determine this "quantitative" coil volume, based on whether the probe is equipped or not with a gradient coil. In addition, to improve the sensitivity and the accuracy, an optimum rotor packing design is described, which allows the sample volume of the rotor to be matched to the quantitative coil volume. Experiments conducted on adamantane and NaCl, which are representative of a soft and hard material, respectively, show that one order of magnitude increase in experimental precision can be achieved with this methodology. Interestingly, the precision can be further improved by using the ERETIC method in order to compensate for most instrumental instabilities.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17703975     DOI: 10.1016/j.jmr.2007.07.006

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  ViP MRI: virtual phantom magnetic resonance imaging.

Authors:  Hervé Saint-Jalmes; Pierre-Antoine Eliat; Johanne Bezy-Wendling; Alejandro Bordelois; Giulio Gambarota
Journal:  MAGMA       Date:  2013-12-15       Impact factor: 2.310

2.  Synthetic signal injection using a single radiofrequency channel.

Authors:  Kenneth I Marro; Donghoon Lee; Eric G Shankland; Clinton M Mathis; Cecil E Hayes
Journal:  J Magn Reson Imaging       Date:  2011-10-05       Impact factor: 4.813

3.  Quantitative in vivo magnetic resonance spectroscopy using synthetic signal injection.

Authors:  Kenneth I Marro; Donghoon Lee; Eric G Shankland; C Mark Mathis; Cecil E Hayes; Seth D Friedman; Martin J Kushmerick
Journal:  PLoS One       Date:  2010-12-28       Impact factor: 3.240

4.  ¹³C SPE MAS measurement of ligand concentration in compressible chromatographic beads.

Authors:  Fredrik Elwinger; Sergey V Dvinskikh; István Furó
Journal:  Magn Reson Chem       Date:  2015-06-06       Impact factor: 2.447

5.  High-resolution magic angle spinning (1) H NMR measurement of ligand concentration in solvent-saturated chromatographic beads.

Authors:  Fredrik Elwinger; István Furó
Journal:  Magn Reson Chem       Date:  2016-01-20       Impact factor: 2.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.