Literature DB >> 17703458

Cervical cytology reading times: a comparison between ThinPrep Imager and conventional methods.

Elizabeth Davey1, Les Irwig, Petra Macaskill, Siew F Chan, Jefferson D'Assuncao, Adele Richards, Annabelle Farnsworth.   

Abstract

We aimed to compare the times cytologists spend reviewing cervical cytology slides processed by the ThinPrep Imager (TPI) with times they spend examining conventional cytology (CC) slides. We also aimed to examine the effect of cytologists' experience on reading times. Using a cross-sectional analytical design, we analyzed routine laboratory data, collected retrospectively over 7 months, for 41 cytologists, including paired data for 20 who read both TPI and CC slides. For the 20 cytologists who read both types of cytology, the mean reading rate was 13.3 slides per hour for TPI slides and 6.1 slides per hour for CC slides. The mean within-reader difference between TPI and CC rates was 7.2 slides per hour (P < 0.001). For CC reading, mean times did not differ between those who were additionally trained to read TPI slides and those who only read CC. Slower readers had greater increases in speed when using the TPI compared with CC reading than did faster readers (P < 0.001). More experienced cytologists tended to read CC slides more quickly than did those less experienced, but experience did not affect TPI reading times or within-reader differences in reading times between cytology types. The TPI significantly reduced reading times compared with CC. This reduction was greater amongst slower readers, and was unrelated to experience. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17703458     DOI: 10.1002/dc.20689

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  3 in total

1.  Liquid based cytology in cervical cancer screening.

Authors:  Karin J Denton
Journal:  BMJ       Date:  2007-07-07

2.  Comparison of ThinPrep Integrated Imager-Assisted Screening versus Manual Screening of ThinPrep Liquid-Based Cytology Specimens.

Authors:  Kyoko Tanaka; Daisuke Aoki; Akiko Tozawa-Ono; Nao Suzuki; Kiyoshi Takamatsu; Masaru Nakamura; Hajime Tsunoda; Shigeo Seino; Noriko Kobayashi; Takefumi Shirayama; Fumiaki Takahashi
Journal:  Acta Cytol       Date:  2020-06-12       Impact factor: 2.319

3.  Accuracy of reading liquid based cytology slides using the ThinPrep Imager compared with conventional cytology: prospective study.

Authors:  Elizabeth Davey; Jefferson d'Assuncao; Les Irwig; Petra Macaskill; Siew F Chan; Adele Richards; Annabelle Farnsworth
Journal:  BMJ       Date:  2007-06-29
  3 in total