Multitomographic evaluation of the dental effects of two different rapid palatal expansion appliances.

Hüseyin Olmez1, Erol Akin, Seniz Karaçay.   

Abstract

Rapid palatal expansion (RPE) is widely used in the treatment of transverse maxillary deficiencies. Generally, there are two types of RPE appliances: banded and bonded expanders. The purpose of this prospective study was to compare the dental effects of banded and bonded appliances. The study consisted of 23 patients (13 females and 10 males) with a bilateral maxillary deficiency. Twelve patients (seven females and five males) with a mean age of 14.8 +/- 0.3 years were treated with banded RPE and 11 patients (six females and five males) with a mean age of 15.1 +/- 0.7 years with bonded RPE. Multitomographic radiographs were taken before (T0) and at the end (T1) of expansion while the patients were wearing an acrylic mandibular appliance in which ball bearings and bars were embedded. Statistical analyses of the measurements at T0 and T1 were undertaken with a paired t-test, and the difference between the groups assesed with a Student's t-test. In both groups, the angle between the radiographic image of the bar and the axial inclination of the upper first premolar and molar teeth was (5.34 and 2.73 degrees for the right premolars, 5.17 and 2.28 degrees for the left premolars, 11.83 and 3.73 degrees for the right molars, and 9.75 and 5.64 degrees for the left molars in the banded and bonded groups, respectively. The distance from the vestibular cortical plate to the palatal root of these teeth (1.17 and 1.23 mm for the right premolars, 2.46 and 1.09 mm for the left premolars, 2.75 and 0.64 mm for the right molars, 2.23 and 0.96 mm for the left molars in the banded and bonded groups, respectively) increased (both P < 0.01). These increases indicated buccal tipping of the teeth. Comparison of the two groups showed that tipping of the first molar and premolar teeth in the banded group was significantly more than in the bonded group (P < 0.01 and P < 0.001, respectively).

Entities:  

Mesh:

Year:  2007        PMID: 17702798     DOI: 10.1093/ejo/cjm034

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  Differential treatment effects of two anchorage systems for rapid maxillary expansion: a retrospective cephalometric study.

Authors:  Jan Hourfar; Gero Stefan Michael Kinzinger; Björn Ludwig; Julia Spindler; Jörg Alexander Lisson
Journal:  J Orofac Orthop       Date:  2016-06-07       Impact factor: 1.938

2.  To beam or not to beam: that is the question.

Authors:  R Lione; L Franchi; E Fanucci; G Laganà; P Cozza
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  Three-dimensional evaluation of skeletal and dental effects of treatment with maxillary skeletal expansion.

Authors:  Craig McMullen; Najla N Al Turkestani; Antonio C O Ruellas; Camila Massaro; Marcus V N N Rego; Marilia S Yatabe; Hera Kim-Berman; James A McNamara; Fernanda Angelieri; Lorenzo Franchi; Peter Ngan; Hong He; Lucia H S Cevidanes
Journal:  Am J Orthod Dentofacial Orthop       Date:  2021-12-31       Impact factor: 2.711

Review 4.  Does rapid maxillary expansion induce adverse effects in growing subjects?

Authors:  Roberta Lione; Lorenzo Franchi; Paola Cozza
Journal:  Angle Orthod       Date:  2012-07-23       Impact factor: 2.079

5.  Rapid maxillary expansion effects: an alternative assessment method by means of cone-beam tomography.

Authors:  Camilo Aquino Melgaço; José Columbano Neto; Estela Maris Jurach; Matilde da Cunha Gonçalves Nojima; Eduardo Franzotti Sant'Anna; Lincoln Issamu Nojima
Journal:  Dental Press J Orthod       Date:  2014 Sep-Oct

6.  Quantitative Evaluation of Midpalatal Suture Opening and Its Relation with Zygomaticomaxillary Suture Status in Patients Aged 7-25 Years Using Cone Beam Computed Tomography Images: In an Iranian Population.

Authors:  Zahra Dalili Kajan; Naid Karimi Nasab; Neda Eghrari
Journal:  Contemp Clin Dent       Date:  2018-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.