Literature DB >> 17700116

A standardized digital photography system with computerized eyelid measurement analysis.

Andrew G Coombes1, Charanjit S Sethi, W Niall Kirkpatrick, Norman Waterhouse, Martin H Kelly, Naresh Joshi.   

Abstract

BACKGROUND: The authors have developed a slit-lamp mounted digital photography system. This ensures that the patient's head is consistently positioned in the same plane in relation to the camera and generates standardized images of the eyelids, which are then analyzed using commercially available computer measurement software. The aim of this study was to assess the repeatability and reproducibility of this system compared with traditional methods of eyelid measurement.
METHODS: Both eyes of 10 patients were photographed and then measured by three clinicians using a handheld ruler for five eyelid parameters (i.e., palpebral aperture, superior marginal reflex distance, inferior scleral show, levator function, and upper eyelid skin crease height). The photographs were then assessed using computer software by the same clinicians (twice by a consultant and once by a clinical fellow and a specialist registrar). At all times, each observer was masked to their colleagues' results. Data were analyzed using Bland-Altman plots.
RESULTS: There was a good level of agreement between measurements obtained by computer analysis of digital photographs and measurements obtained by traditional methods. A higher level of reproducibility (interobserver variability) was demonstrated in all digital measurements compared with those obtained by handheld ruler. Repeatability (intraobserver variability) with the digital photograph technique was also high and consistent for each of the five eyelid parameters.
CONCLUSIONS: These results suggest that a digital photography system with computer analysis is comparable to, and offers advantages over, traditional methods of measurement. This system offers a simple, standardized, and rapid method of patient assessment with important applications in electronic patient records, audit, and research.

Entities:  

Mesh:

Year:  2007        PMID: 17700116     DOI: 10.1097/01.prs.0000270315.53241.10

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  11 in total

Review 1.  Two-Dimensional Analysis of Digital Images through Vector Graphic Editors in Dentistry: New Calibration and Analysis Protocol Based on a Scoping Review.

Authors:  Samuel Rodríguez-López; Matías Ferrán Escobedo Martínez; Luis Junquera; María García-Pola
Journal:  Int J Environ Res Public Health       Date:  2021-04-23       Impact factor: 3.390

2.  Cosmetic outcome of posterior approach ptosis surgery (an American Ophthalmological Society thesis).

Authors:  Robert A Goldberg; Helen Lew
Journal:  Trans Am Ophthalmol Soc       Date:  2011-12

3.  A novel method to measure margin reflex distance using the autorefractometer.

Authors:  Demet Yolcu; Sibel Ozdogan
Journal:  Int Ophthalmol       Date:  2021-11-05       Impact factor: 2.031

4.  Photographic assessment of eyelid position using a simple measurement tool paired with cell phone photography in a pediatric population.

Authors:  S Grace Prakalapakorn; Marguerite C Weinert; Sandra S Stinnett
Journal:  J AAPOS       Date:  2021-10-14       Impact factor: 1.325

5.  Anthropometric analysis of palpebral fissure dimensions and its position in South Indian ethnic adults.

Authors:  P Vasanthakumar; Pramod Kumar; Mohandas Rao
Journal:  Oman Med J       Date:  2013-01

6.  Analysis of surgical outcome after upper eyelid surgery by computer vision algorithm using face and facial landmark detection.

Authors:  İlke Bahçeci Şimşek; Can Şirolu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-05-08       Impact factor: 3.117

7.  Comparison of Blepharoptosis Correction Using Müller-aponeurosis Composite Flap Advancement and Frontalis Muscle Transfer.

Authors:  David Dae Hawan Park; Anwar Ramadhan; Dong Gil Han; Jeong Su Shim; Yong Jig Lee; Won Ho Ha; Byung Kwon Lee
Journal:  Plast Reconstr Surg Glob Open       Date:  2014-09-08

8.  Ten Years of Results of Modified Frontalis Muscle Transfer for the Correction of Blepharoptosis.

Authors:  Woo Jeong Kim; Dae Hwan Park; Dong Gil Han
Journal:  Arch Plast Surg       Date:  2016-03-18

9.  The utility of margin-reflex distance in determining the type of surgical intervention for congenital blepharoptosis.

Authors:  Ozlem Ural; Mehmet Cem Mocan; Anıl Dolgun; Ugur Erdener
Journal:  Indian J Ophthalmol       Date:  2016-10       Impact factor: 1.848

10.  Evolution of photography in maxillofacial surgery: from analog to 3D photography - an overview.

Authors:  Heidrun Schaaf; Christoph Yves Malik; Hans-Peter Howaldt; Philipp Streckbein
Journal:  Clin Cosmet Investig Dent       Date:  2009-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.