Literature DB >> 17699314

Relationship between blood flow in central venous catheters and hemodialysis adequacy.

Louise M Moist1, Brenda R Hemmelgarn, Charmaine E Lok.   

Abstract

Central venous catheter dysfunction is a frequent problem and often is defined as a blood flow <300 ml/min. This prospective, cross-sectional study included 259 patients and examined the relationship between catheter blood flow and dialysis adequacy as measured by urea reduction ratio (URR), single pool urea kinetics, and online effective ionic dialysance clearance. Dialysis adequacy at blood flow rates of <300, <275, and <250 ml/min; sensitivity; specificity; and positive and negative predictive values were calculated. Mean blood flow was 352 ml/min (SD +/- 48.8). Mean blood flow <300 ml/min occurred in 10.5% of the patients, and only 26% had a URR of <65%. Maximum blood flows <300 ml/min occurred in 6.9% of patients, and only 22.2% had URR <65%. The positive predictive value of mean blood flow of <300 and <275 ml/min to predict a URR <65% was 22 and 40%, respectively. Using receiver operator characteristic curves, the area under the curve was not significantly different for blood flows of 300, 275, or 250 ml/min. This study indicates that mean blood flows <300 ml/min are not commonly associated with dialysis inadequacy. Setting a single blood flow cut point of <300 ml/min to define the need for intervention will result in a significant number of unnecessary interventions. There is a need to reexamine the definition of catheter dysfunction and expand the definition beyond blood flow rates.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17699314     DOI: 10.2215/CJN.01090306

Source DB:  PubMed          Journal:  Clin J Am Soc Nephrol        ISSN: 1555-9041            Impact factor:   8.237


  10 in total

1.  Characterization of the cylindrical electrospun nanofibrous polysulfone membrane for hemodialysis with modelling approach.

Authors:  Farideh Mohammadi; Farzaneh Mohammadi; Zeynab Yavari
Journal:  Med Biol Eng Comput       Date:  2021-07-17       Impact factor: 2.602

Review 2.  Standardized definitions for hemodialysis vascular access.

Authors:  Timmy Lee; Michele Mokrzycki; Louise Moist; Ivan Maya; Miguel Vazquez; Charmaine E Lok
Journal:  Semin Dial       Date:  2011-09-09       Impact factor: 3.455

3.  Patterns of Hemodialysis Catheter Dysfunction Defined According to National Kidney Foundation Guidelines As Blood Flow <300 mL/min.

Authors:  Robert I Griffiths; Britt B Newsome; Geoffrey A Block; Robert J Herbert; Mark D Danese
Journal:  Int J Nephrol       Date:  2011-12-08

4.  Impact of hemodialysis catheter dysfunction on dialysis and other medical services: an observational cohort study.

Authors:  Robert I Griffiths; Britt B Newsome; Grace Leung; Geoffrey A Block; Robert J Herbert; Mark D Danese
Journal:  Int J Nephrol       Date:  2012-02-12

5.  Risk factors associated with hemodialysis central venous catheter malfunction; a retrospective analysis of a randomized controlled trial.

Authors:  David R Ward; Louise M Moist; Jennifer M MacRae; Nairne Scott-Douglas; Jianguo Zhang; Marcello Tonelli; Charmaine E Lok; Steven D Soroka; Brenda R Hemmelgarn
Journal:  Can J Kidney Health Dis       Date:  2014-07-08

6.  A Retrospective Study of Preferable Alternative Route to Right Internal Jugular Vein for Placing Tunneled Dialysis Catheters: Right External Jugular Vein versus Left Internal Jugular Vein.

Authors:  Pei Wang; Yufei Wang; Yingjin Qiao; Sijie Zhou; Xianhui Liang; Zhangsuo Liu
Journal:  PLoS One       Date:  2016-01-11       Impact factor: 3.240

7.  Arterial line pressure control enhanced extracorporeal blood flow prescription in hemodialysis patients.

Authors:  Franklin G Mora-Bravo; Alfonso Mariscal; Juan P Herrera-Felix; Salvador Magaña; Guadalupe De-La-Cruz; Nelly Flores; Laura Rosales; Martha Franco; Héctor Pérez-Grovas
Journal:  BMC Nephrol       Date:  2008-11-24       Impact factor: 2.388

8.  Recommended Clinical Trial End Points for Dialysis Catheters.

Authors:  Michael Allon; Deborah J Brouwer-Maier; Kenneth Abreo; Kevin M Baskin; Kay Bregel; Deepa H Chand; Andrea M Easom; Leonard Mermel; Michele H Mokrzycki; Priti R Patel; Prabir Roy-Chaudhury; Surendra Shenoy; Rudolph P Valentini; Haimanot Wasse
Journal:  Clin J Am Soc Nephrol       Date:  2017-07-20       Impact factor: 8.237

9.  Comparison of Complications of Arteriovenous Fistula with Permanent Catheter in Hemodialysis Patients: A Six-month Follow-up.

Authors:  Ali Momeni; Saeed Mardani; Maryam Kabiri; Masoud Amiri
Journal:  Adv Biomed Res       Date:  2017-08-28

10.  Diabetes decreases patency of tunneled catheters in hemodialysis patients after first effective thrombolysis with urokinase.

Authors:  Dominika Wójtowicz; Dominika Cholewa; Anna M Faba; Beata Domańska; Joanna Kokoszka; Konrad Kopacz; Rafał Ficek; Tomasz Irzyniec; Sylwia E Rotkegel; Jerzy Chudek
Journal:  Ren Fail       Date:  2018-11       Impact factor: 2.606

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.