Literature DB >> 17697799

Hand carried echocardiography screening for LV systolic dysfunction in a pulmonary function laboratory.

James N Kirkpatrick1, Syed Nasir Ghani, Kirk T Spencer.   

Abstract

AIMS: Dyspnea is a common indication for pulmonary evaluation but also a common symptom in heart failure. Identification of dyspneic patients with significant LV systolic dysfunction is critical because of high morbidity of untreated heart failure. We sought to determine whether screening patients referred for pulmonary function testing (PFT) using a hand carried ultrasound (HCU) device could identify LV systolic dysfunction.
METHODS: Forty-nine subjects were recruited from a pulmonary function lab to undergo a brief echocardiographic examination by an internist using a HCU device. All subjects also received an examination with a full-featured echocardiogram machine as a gold standard.
RESULTS: All subjects with normal PFT had normal LV systolic function. Among subjects with abnormal PFT, 6 (15%) had LV systolic dysfunction and the remainder had normal LV systolic function. No subjects with LV systolic dysfunction by full-featured echocardiograms were missed by the HCU (sensitivity 100%, specificity 95%, negative predictive value 100%, positive predictive value 75%).
CONCLUSIONS: LV systolic dysfunction is prevalent among patients with pulmonary disease and can be accurately screened for by a physician using a hand carried ultrasound device with subsequent confirmation with complete echocardiography.

Entities:  

Mesh:

Year:  2007        PMID: 17697799     DOI: 10.1016/j.euje.2007.06.013

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  4 in total

Review 1.  Handcarried echocardiography to assess hemodynamics in acute decompensated heart failure.

Authors:  Sascha N Goonewardena; Kirk T Spencer
Journal:  Curr Heart Fail Rep       Date:  2010-12

Review 2.  Focused cardiac ultrasound: where do we stand?

Authors:  Kirk T Spencer
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

3.  Does physician experience influence the interpretability of focused echocardiography images performed by a pocket device?

Authors:  Xavier Bobbia; Christophe Pradeilles; Pierre Géraud Claret; Camille Soullier; Patricia Wagner; Yann Bodin; Claire Roger; Guillaume Cayla; Laurent Muller; Jean Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-07-07       Impact factor: 2.953

4.  Diagnostic accuracy of handheld cardiac ultrasound device for assessment of left ventricular structure and function: systematic review and meta-analysis.

Authors:  Sam Jenkins; Samer Alabed; Andrew Swift; Gabriel Marques; Alisdair Ryding; Chris Sawh; James Wardley; Benoy Nalin Shah; Peter Swoboda; Roxy Senior; Robin Nijveldt; Vassilios S Vassiliou; Pankaj Garg
Journal:  Heart       Date:  2021-08-06       Impact factor: 5.994

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.