Literature DB >> 17696631

Changes in coronary flow reserve following stent implantation in the swine descending thoracic aorta.

Achilles A Zacharoulis1, Sophia M Arapi, George A Lazaros, Apostolos I Karavidas, Apostolos A Zacharoulis.   

Abstract

PURPOSE: To evaluate coronary flow reserve (CFR) changes following stent implantation in the descending thoracic aorta (DTA) of a porcine model.
METHODS: Six pigs (3 males; 40 to 44 kg) were anesthetized and kept on mechanical ventilation. A 6-F guiding right Judkins catheter was advanced under fluoroscopy to the right coronary artery, and a pressure wire with a temperature sensor was placed within the vessel lumen at a distance of 4 cm from the ostium. CFR was estimated by the thermodilution method before and after maximal coronary vasodilation with 20 mg of intracoronary papaverine. Aortography was also performed to measure aortic diameter. Subsequently, a self-expanding vascular stent was deployed into the DTA just below the left subclavian artery (LSA), and CFR was measured again. All animals were maintained for 3 weeks; at the end of this period, a further CFR was calculated using the same procedure.
RESULTS: The mean aortic diameter below the LSA was 12.15+/-0.15 mm. Following stent deployment, the mean aortic diameter measured at the stented segment was 12.58+/-0.11 (p=0.001 versus baseline). The mean CFR value was 4.70+/-2.00 before stent implantation, 2.68+/-0.86 immediately after, and 4.05+/-1.15 at 3 weeks after stenting. Accordingly, CFR values were significantly depressed immediately after stent placement compared with baseline (p=0.027). However, CFR values obtained 3 weeks following stent deployment were similar to the initial values (p=0.59).
CONCLUSION: Stent deployment in the normal swine DTA produces a significant immediate decrease in CFR, which is attenuated 3 weeks later. The clinical impact of CFR changes following DTA endografting remain to be elucidated.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17696631     DOI: 10.1177/152660280701400417

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

1.  Cardiac remodelling following thoracic endovascular aortic repair for descending aortic aneurysms.

Authors:  Theodorus M J van Bakel; Christopher J Arthurs; Foeke J H Nauta; Kim A Eagle; Joost A van Herwaarden; Frans L Moll; Santi Trimarchi; Himanshu J Patel; C Alberto Figueroa
Journal:  Eur J Cardiothorac Surg       Date:  2019-06-01       Impact factor: 4.191

2.  Influence of shape-memory stent grafts on local aortic compliance.

Authors:  J Concannon; K M Moerman; N Hynes; S Sultan; J P McGarry
Journal:  Biomech Model Mechanobiol       Date:  2021-09-19

3.  An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection.

Authors:  Liam Morris; Paul Tierney; Niamh Hynes; Sherif Sultan
Journal:  Front Cardiovasc Med       Date:  2022-03-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.