Literature DB >> 17696214

Experimental renal preservation by normothermic resuscitation perfusion with autologous blood.

A Bagul1, S A Hosgood, M Kaushik, M D Kay, H L Waller, M L Nicholson.   

Abstract

BACKGROUND: Normothermic perfusion (NP) has the potential to improve metabolic support and maintain the viability of ischaemically damaged organs. This study investigated the effects of NP compared with current methods of organ preservation in a model of controlled non-heart-beating donor (NHBD) kidneys.
METHODS: Porcine kidneys (n = 6 in each group) were subjected to 10 min warm ischaemia and then preserved as follows: 2 h cold storage (CS) in ice (CS2 group), 18 h CS (CS18 group), 18 h cold machine perfusion (CP group) or 16 h CS + 2 h NP (NP group). Renal haemodynamics and function were measured during 3 h reperfusion with autologous blood using an isolated organ perfusion system.
RESULTS: Increasing CS from 2 to 18 h reduced renal blood flow (mean(s.d.) area under the curve (AUC) 444(57) versus 325(70) ml per 100 g; P = 0.004), but this was restored by NP (563(119) ml per 100 g; P = 0.035 versus CS18). Renal function was also better in CS2, CP and NP groups than in the CS18 group (mean(s.d.) serum creatinine fall 92(6), 79(9) and 64(17) versus 44(13) per cent respectively; P = 0.001). The AUC for serum creatinine was significantly lower with CS for 2 h than for 18 h (mean(s.d.) 1102(2600) versus 2156(401) micromol/l.h; P = 0.001), although values in CP and NP groups were not significantly different from those in the CS2 group (1354(300) and 1756(280) micromol/l.h respectively). Two hours of NP increased the adenosine 3'-triphosphate : adenosine 3'-diphosphate ratio to a significantly higher level than the preperfusion values in all other groups (P = 0.046).
CONCLUSION: NP with oxygenated blood was able to restore depleted ATP levels and reverse some of the deleterious effects of CS. Copyright (c) 2007 British Journal of Surgery Society Ltd.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17696214     DOI: 10.1002/bjs.5909

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  26 in total

Review 1.  New strategies to optimize kidney recovery and preservation in transplantation.

Authors:  Delphine Bon; Nicolas Chatauret; Sébastien Giraud; Raphael Thuillier; Frédéric Favreau; Thierry Hauet
Journal:  Nat Rev Nephrol       Date:  2012-05-01       Impact factor: 28.314

2.  Comparison of normothermic and hypothermic perfusion in porcine kidneys donated after cardiac death.

Authors:  Matthew F Blum; Qiang Liu; Basem Soliman; Paul Dreher; Toshihiro Okamoto; Emilio D Poggio; David A Goldfarb; William M Baldwin; Cristiano Quintini
Journal:  J Surg Res       Date:  2017-04-20       Impact factor: 2.192

Review 3.  Organ preservation: from the past to the future.

Authors:  Lei Jing; Leeann Yao; Michael Zhao; Li-Ping Peng; Mingyao Liu
Journal:  Acta Pharmacol Sin       Date:  2018-03-22       Impact factor: 6.150

4.  Continuous Normothermic Ex Vivo Kidney Perfusion Improves Graft Function in Donation After Circulatory Death Pig Kidney Transplantation.

Authors:  J Moritz Kaths; Juan Echeverri; Yi Min Chun; Jun Yu Cen; Nicolas Goldaracena; Ivan Linares; Luke S Dingwell; Paul M Yip; Rohan John; Darius Bagli; Istvan Mucsi; Anand Ghanekar; David R Grant; Lisa A Robinson; Markus Selzner
Journal:  Transplantation       Date:  2017-04       Impact factor: 4.939

5.  Prolonged ex-vivo normothermic kidney perfusion: The impact of perfusate composition.

Authors:  Merel B F Pool; Tim L Hamelink; Harry van Goor; Marius C van den Heuvel; Henri G D Leuvenink; Cyril Moers
Journal:  PLoS One       Date:  2021-05-18       Impact factor: 3.240

6.  Machine perfusion preservation versus static cold storage for deceased donor kidney transplantation.

Authors:  Samuel J Tingle; Rodrigo S Figueiredo; John Ag Moir; Michael Goodfellow; David Talbot; Colin H Wilson
Journal:  Cochrane Database Syst Rev       Date:  2019-03-15

7.  Metabolomic perfusate analysis during kidney machine perfusion: the pig provides an appropriate model for human studies.

Authors:  Jay Nath; Alison Guy; Thomas B Smith; Mark Cobbold; Nicholas G Inston; James Hodson; Daniel A Tennant; Christian Ludwig; Andrew R Ready
Journal:  PLoS One       Date:  2014-12-12       Impact factor: 3.240

Review 8.  Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis.

Authors:  Ahmer M Hameed; Henry C Pleass; Germaine Wong; Wayne J Hawthorne
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

Review 9.  Renal Delivery of Pharmacologic Agents During Machine Perfusion to Prevent Ischaemia-Reperfusion Injury: From Murine Model to Clinical Trials.

Authors:  Rossana Franzin; Alessandra Stasi; Marco Fiorentino; Simona Simone; Rainer Oberbauer; Giuseppe Castellano; Loreto Gesualdo
Journal:  Front Immunol       Date:  2021-07-06       Impact factor: 7.561

10.  Uncontrolled donors with controlled reperfusion after sixty minutes of asystole: a novel reliable resource for kidney transplantation.

Authors:  Oleg N Reznik; Andrei E Skvortsov; Alexander O Reznik; Alexey N Ananyev; Alexey P Tutin; Denis O Kuzmin; Sergey F Bagnenko
Journal:  PLoS One       Date:  2013-05-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.