Literature DB >> 17695610

Bond durability of composite luting agents to ceramic when exposed to long-term thermocycling.

M Peumans1, K Hikita, J De Munck, K Van Landuyt, A Poitevin, P Lambrechts, B Van Meerbeek.   

Abstract

PURPOSE: This study evaluated the effect of thermocycling on the microtensile bond strength of four adhesive luting agents to GN-I CAD-CAM ceramic. The hypothesis tested was that thermocycling did not affect bonding effectiveness, irrespective of the luting agents used.
MATERIALS AND METHODS: Ceramic specimens of two different sizes (6x8x3 mm; 13x8x4 nm) were fabricated from GN-I CAD-CAM ceramic blocks (GC) using a low-speed diamond saw. Two different sized porcelain discs were bonded with one of the four composite luting agents (Linkmax [LM], Panavia [PN], RelyX Unicem [UN] and Variolink II [VL]) according to the manufacturer's instructions. The specimens were stored for 24 hours in distilled water at 37 degrees C and subjected to 0; 10,000; 20,000 and 40,000 thermocycles prior to microTBS testing. Two-way analysis of variance was used to test the influence of luting cement, thermocycling and interaction between both (p < 0.05). The Tukey HSD test determined statistical differences in microTBS for each luting composite between the different thermocycling conditions (p < 0.05). The mode of failure was determined at a magnification of 50x using a stereomicroscope (Wild M5A).
RESULTS: Two-way ANOVA revealed that microtensile bond strength was affected by the luting cement, thermocycling and a combination of both. No difference in bond strength between Linkmax, Panavia F and Variolink II was noticed after 24 hours of water storage (LM: 47.6 MPa; PN: 41 MPa; VL: 36 MPa). RelyX Unicem scored significantly lower than Linkmax and Panavia F (UN: 24.2 MPa). The influence of thermocycling on bond strength was different for the four luting cements. Using Variolink II, the bond strength remained stable after 40,000 thermocycles (43.6 MPa). Linkmax showed a significant decrease in bond strength after 10,000 (26 MPa) and 40,000 thermocycles (14.8 MPa). Panavia F and RelyX Unicem were the most negatively influenced, as all specimens failed prior to testing (pre-testing failures) when the specimens were thermocycled 10,000 and 20,000 times or longer, respectively. Regarding the failure mode, there was a correlation between bond strength and type of failure. Initially, a combination of adhesive and mixed adhesive-cohesive failures was noticed. The percentage of adhesive failures increased, together with a decrease in bond strength.
CONCLUSION: It was concluded that there were significant differences among the four resin composite cements in terms of their bonding effectiveness to CAD-CAM ceramic after thermocycling. The varying degrees of bonding effectiveness of these adhesive luting agents highlight the need for material specifications.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17695610     DOI: 10.2341/06-106

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  2 in total

1.  Bonding all-ceramic restorations with two resins cement techniques: a clinical report of three-year follow-up.

Authors:  Rodolfo Bruniera Anchieta; Eduardo Passos Rocha; Erika Oliveira de Almeida; Amilcar Chagas Freitas Junior; Ana Paula Martini
Journal:  Eur J Dent       Date:  2011-08

2.  A Comparative Study on the Mechanical Properties of a Polymer-Infiltrated Ceramic-Network Material Used for the Fabrication of Hybrid Abutment.

Authors:  Salim Ongun; Sevcan Kurtulmus-Yilmaz; Gökçe Meriç; Mutahhar Ulusoy
Journal:  Materials (Basel)       Date:  2018-09-11       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.