Literature DB >> 17692590

Strength estimation of different designs of ceramic inlays and onlays in molars based on the Tsai-Wu failure criterion.

Beata Dejak1, Andrzej Mlotkowski, Maciej Romanowicz.   

Abstract

STATEMENT OF PROBLEM: Successful restoration of large molar defects is a serious clinical problem. Studies on the strength of teeth restored with ceramic restorations of various designs have provided conflicting results.
PURPOSE: The purpose of this study was to determine the shapes of large MOD ceramic restorations in molars most likely to prevent failure and to produce a favorable distribution of contact stresses between the cement and teeth during mastication.
MATERIAL AND METHODS: The study was performed using a finite element analysis with contact elements. Eight 2-dimensional models of mandibular first molars with the following designs of MOD ceramic restorations were created: an inlay with a butt joint margin, an inlay with a beveled margin, an onlay with a butt joint margin, and an onlay with a rounded shoulder margin. The restorations had 3-mm or 5-mm isthmus widths. Models of opposing maxillary crowns were also developed. Computational simulation of mastication of boluses in the frontal plane was conducted, during which the stresses occurring in the ceramic restorations, cement, and tooth structure were calculated. The Tsai-Wu failure criterion was used to evaluate the strength of the materials. Contact stresses at the adhesive interface between the tooth structure and resin cement around these restorations were analyzed.
RESULTS: According to the Tsai-Wu failure criterion, the margin of the beveled inlay and the surrounding tissue could be damaged during masticatory simulation. At the junction of the butt joint margin inlay and enamel, contact tensile stresses appeared. The lowest inverse of the Tsai-Wu strength ratio index appeared in the onlay with a rounded shoulder margin. At the adhesive interfaces around margins of large onlays, compressive contact stresses occurred.
CONCLUSIONS: For the large molar MOD ceramic restorations tested, the lowest values of the inverse of the Tsai-Wu strength ratio index and a favorable distribution of contact stresses between restoration and tissues appeared in the onlay with a rounded shoulder margin.

Mesh:

Year:  2007        PMID: 17692590     DOI: 10.1016/S0022-3913(07)60042-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  11 in total

1.  Using occlusal wear information and finite element analysis to investigate stress distributions in human molars.

Authors:  Stefano Benazzi; Ottmar Kullmer; Ian R Grosse; Gerhard W Weber
Journal:  J Anat       Date:  2011-05-25       Impact factor: 2.610

2.  [Three-year retrospective clinical evaluation of pulp-less molars with defects of varying degree repaired by cast ceramic onlays of three marginal types].

Authors:  Wei-Lin Qiang; Yu-Xuan Li; Gang Liu; Li-Hong Zhang; Jing-Yang Zhang; Wen-Jin Cao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-10-01

3.  Comparison of occlusal loading conditions in a lower second premolar using three-dimensional finite element analysis.

Authors:  Stefano Benazzi; Ian R Grosse; Giorgio Gruppioni; Gerhard W Weber; Ottmar Kullmer
Journal:  Clin Oral Investig       Date:  2013-03-16       Impact factor: 3.573

4.  Exploring the biomechanics of taurodontism.

Authors:  Stefano Benazzi; Huynh N Nguyen; Ottmar Kullmer; Jean-Jacques Hublin
Journal:  J Anat       Date:  2014-11-18       Impact factor: 2.610

5.  Influence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations.

Authors:  Petra C Guess; Stefan Schultheis; Martin Wolkewitz; Yu Zhang; Joerg R Strub
Journal:  J Prosthet Dent       Date:  2013-10       Impact factor: 3.426

6.  Interpreting finite element results for brittle materials in endodontic restorations.

Authors:  Antonio Pérez-González; José L Iserte-Vilar; Carmen González-Lluch
Journal:  Biomed Eng Online       Date:  2011-06-02       Impact factor: 2.819

7.  Effect of restoration material on stress distribution on partial crowns: A 3D finite element analysis.

Authors:  Serhat Emre Özkir
Journal:  J Dent Sci       Date:  2018-05-05       Impact factor: 2.080

8.  The evolutionary paradox of tooth wear: simply destruction or inevitable adaptation?

Authors:  Stefano Benazzi; Huynh Nhu Nguyen; Dieter Schulz; Ian R Grosse; Giorgio Gruppioni; Jean-Jacques Hublin; Ottmar Kullmer
Journal:  PLoS One       Date:  2013-04-24       Impact factor: 3.240

9.  Unravelling the functional biomechanics of dental features and tooth wear.

Authors:  Stefano Benazzi; Huynh Nhu Nguyen; Ottmar Kullmer; Jean-Jacques Hublin
Journal:  PLoS One       Date:  2013-07-23       Impact factor: 3.240

10.  Stress distribution in premolars restored with inlays or onlays: 3D finite element analysis.

Authors:  Hongso Yang; Chan Park; Jin-Ho Shin; Kwi-Dug Yun; Hyun-Pil Lim; Sang-Won Park; Hyunju Chung
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

View more