Microdosimetric evaluation of secondary particles in a phantom produced by carbon 290 MeV/nucleon ions at HIMAC.

Satoru Endo1, Masashi Takada, Yoshihiko Onizuka, Kenichi Tanaka, Naoko Maeda, Masayori Ishikawa, Nobuyuki Miyahara, Naofumi Hayabuchi, Kiyoshi Shizuma, Masaharu Hoshi.   

Abstract

Microdosimetric single event spectra as a function of depth in a phantom for the 290 MeV/nucleon therapeutic carbon beam at HIMAC were measured by using a tissue equivalent proportional counter (TEPC). Two types of geometries were used: one is a fragment particle identification measurement (PID-mode) with time of flight (TOF) method without a backward phantom, and the other is an in-phantom measurement (IPM-mode) with a backward phantom. On the PID-mode geometry, fragments produced by carbon beam in a phantom are identified by the DeltaE-TOF distribution between two scintillation counters positioned up- and down-stream relative to the tissue equivalent proportional counter (TEPC). Lineal energy distributions for carbon and five ion fragments (proton, helium, lithium, beryllium and boron) were obtained in the lineal-energy range of 0.1-1000 keV/microm at eight depths (7.9-147.9 mm) in an acrylic phantom. In the IPM-mode geometry, the total lineal energy distributions measured at eight depths (61.9-322.9 mm) were compared with the distributions in the PID-mode. Both spectra are consistent with each other. This shows that the PID-mode measurement can be discussed as the equivalent of the phantom measurement. The dose distribution of the carbon beam and fragments were obtained separately. In the depth dose curve, the Bragg peak was observed. Relative biological effectiveness (RBE) for the carbon beam in the acrylic phantom was obtained based on a biological response function as a lineal-energy. The RBE of carbon beam had a maximum of 4.5 at the Bragg peak. Downstream of the Bragg peak, the RBE rapidly decreases. The RBE of fragments is dominated by Boron particles around the Bragg peak region.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17690533     DOI: 10.1269/jrr.07016

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  3 in total

1.  Measurement of microdosimetric spectra produced from a 290 MeV/n Spread Out Bragg Peak carbon beam.

Authors:  Satoru Endo; Masashi Takada; Hiroki Tanaka; Yoshihiko Onizuka; Kenichi Tanaka; Nobuyuki Miyahara; Hiromi Baba; Ayumu Oishi; Masayori Ishikawa; Masaharu Hoshi; Shinzo Kimura; Masakazu Minematsu; Yuki Morimune; Yasuaki Kojima; Kiyoshi Shizuma
Journal:  Radiat Environ Biophys       Date:  2010-04-18       Impact factor: 1.925

2.  The microdosimetric extension in TOPAS: development and comparison with published data.

Authors:  Hongyu Zhu; Yizheng Chen; Wonmo Sung; Aimee L McNamara; Linh T Tran; Lucas N Burigo; Anatoly B Rosenfeld; Junli Li; Bruce Faddegon; Jan Schuemann; Harald Paganetti
Journal:  Phys Med Biol       Date:  2019-07-11       Impact factor: 3.609

3.  In silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy.

Authors:  Masayoshi Yamada; Hiraku Sato; Yoshiro Ieko; Yuya Miyasaka; Takayuki Kanai; Natsuko Yano; Takashi Ono; Hiroko Akamatsu; Mayumi Harada; Mayumi Ichikawa; Yasushi Teranishi; Yasuhiro Kikuchi; Kenji Nemoto
Journal:  Radiat Oncol       Date:  2019-11-21       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.