Literature DB >> 17688062

Angiographically occult spinal dural arteriovenous fistula located using selective computed tomography angiography. Case report.

Taku Sugawara1, Yoshitaka Hirano, Yasunobu Itoh, Hiroyuki Kinouchi, Satoshi Takahashi, Kazuo Mizoi.   

Abstract

Spinal dural arteriovenous fistula (DAVF) is the most common type of spinal arteriovenous malformation and may cause progressive myelopathy but is usually treatable in the early stages by direct surgery or intravascular embolization. Selective spinal angiography has been the gold standard for diagnosis, but angiographically occult DAVF is not uncommon. A 67-year-old man presented with a 2-year history of progressive paraparesis. Magnetic resonance (MR) imaging demonstrated segmental atrophy of the spinal cord and dilated coronary veins on the dorsal surface of the spinal cord. A DAVF was suspected, but repeated selective angiography failed to demonstrate the fistula. Findings from spoiled gradient echo MR imaging suggested that the draining vein flowed into the dilated venous plexus at the T-9 level. Selective computed tomography (CT) angiography of the right T-9 intercostal artery confirmed the location of the fistula. The authors successfully occluded the draining vein through surgery, and they observed that the fistula was low flow. The patient exhibited improvement in his symptoms, and postoperative MR imaging confirmed closure of the fistula. Selective CT angiography is useful in locating the draining vein of angiographically occult DAVF and therefore minimizing the extent of the surgical procedure.

Entities:  

Mesh:

Year:  2007        PMID: 17688062     DOI: 10.3171/SPI-07/08/215

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  2 in total

1.  3D C-arm conebeam CT angiography as an adjunct in the precise anatomic characterization of spinal dural arteriovenous fistulas.

Authors:  T D Aadland; K R Thielen; T J Kaufmann; J M Morris; G Lanzino; D F Kallmes; B A Schueler; H Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-22       Impact factor: 3.825

2.  Application of 4D-CTA using 320-row area detector computed tomography on spinal arteriovenous fistulae: initial experience.

Authors:  Satoshi Yamaguchi; Masaaki Takeda; Takafumi Mitsuhara; Shiro Kajihara; Kazutoshi Mukada; Kuniki Eguchi; Yosuke Kajihara; Kohei Takemoto; Kazuhiko Sugiyama; Kaoru Kurisu
Journal:  Neurosurg Rev       Date:  2012-11-30       Impact factor: 3.042

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.