Literature DB >> 17687853

[Hemodynamic changes induced by positive pressure capnothorax during thoracoscopic thymectomy].

Dana Tomescu1, B Grigorescu, R Nitulescu, V Tomulescu, I Popescu, D Tulbure.   

Abstract

Low-flow insufflation of CO2 into the thorax helps the surgeon by increasing the surgical field during thoracoscopy, but older studies performed on animals (pigs and dogs) showed that positive pressure capnothorax had negative hemodynamic impact on animals and strongly recommended against using it on humans. We included in our study 24 ASA I-II myasthenic patients (20 females and 4 males) age 29 yo (+/- 10.2) weight 62.8 kg (+/- 10.6) whose thymuses were surgically removed by thoracoscopy. Using thoracic electrical bioimpedance (TEB) we assessed noninvasively cardiac index (CI) stroke index (SI) systemic stroke vascular resistance index (SSVRI) and end diastolic index (EDI). Well known for its hemodynamic stability we chose sevoflurane for induction and maintenance of anesthesia (VIMA). According to Copenhagen scale, adding minimal iv dose of fentanyl (3 mcg/kg) to sevoflurane induction, allowed us to endobronchial intubate in good and excellent conditions. During anesthesia almost all measured parameters (CI, SI, MAP, EDI) recorded statistically significant decrease but with minimal clinical significance. Thus, the maximal drop was measured during application of 10 mm Hg capnothorax: CI and SI dropped by 1.16 1/min/m2 (19%) (p = 0.02) and respectively 16.58 ml/m2 (21%) (p = 0.001). Thereby we are applying low-flow positive pressure insufflation of CO2 into the thorax, to almost all thoracoscopies performed in our clinic.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17687853

Source DB:  PubMed          Journal:  Chirurgia (Bucur)        ISSN: 1221-9118


  3 in total

1.  Arterial pCO2 changes during thoracoscopic surgery with CO2 insufflation and one lung ventilation.

Authors:  D T T Tran; N H Badner; G Nicolaou; W Sischek
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2010

2.  Comparison of two-lung and one-lung ventilation in bilateral video-assisted thoracoscopic extended thymectomy in myasthenia gravis: a retrospective study.

Authors:  Mijung Yun; Gunn Hee Kim; Sung-Chul Ko; Yun Jae Han; Wooshik Kim
Journal:  Anesth Pain Med (Seoul)       Date:  2022-01-06

3.  Obesity is associated with decreased lung compliance and hypercapnia during robotic assisted surgery.

Authors:  Dana Rodica Tomescu; Mihai Popescu; Simona Olimpia Dima; Nicolae Bacalbașa; Șerban Bubenek-Turconi
Journal:  J Clin Monit Comput       Date:  2016-01-28       Impact factor: 2.502

  3 in total