Literature DB >> 17685781

Influence of self-etchant application time on bracket shear bond strength.

Adam Wade Ostby1, Samir E Bishara, John Laffoon, John J Warren.   

Abstract

OBJECTIVE: To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets.
MATERIALS AND METHODS: Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned following the manufacturers' recommendations by rubbing the SEP on the enamel surface for 3 to 5 seconds. The remaining 20 teeth were conditioned using the same SEP, but the application time was increased to 15 seconds. The teeth were debonded within half an hour following initial bonding using a universal testing machine. After debonding, the amount of residual adhesive remaining on the tooth was determined. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi2 test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems.
RESULTS: The mean SBS of the brackets bonded to the teeth subjected to the SEP for 3 to 5 seconds was 8.0+/-4.6 MPa and was not significantly different (t=-0.69, P=.494) from the SBS of the brackets bonded using a 15-second SEP application time (x=8.9+/-3.4 MPa). The comparisons of the ARI scores between the two groups (chi2=2.16) indicated that bracket failure mode was not significantly different (P=.340) for both groups, and most failures were at the bracket-adhesive interface.
CONCLUSION: The present findings indicate that increasing the SEP application from 3 to 5 seconds to 15 seconds does not result in a significant increase in SBS.

Entities:  

Mesh:

Year:  2007        PMID: 17685781     DOI: 10.2319/092006-383

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  5 in total

1.  Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite.

Authors:  Cecilia Goracci; Mariam Margvelashvili; Agostino Giovannetti; Alessandro Vichi; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

2.  Influence of enamel conditioning on the shear bond strength of different adhesives.

Authors:  Lorenz Brauchli; Teodoro Muscillo; Markus Steineck; Andrea Wichelhaus
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

3.  The effects of application time of a self-etching primer and debonding methods on bracket bond strength.

Authors:  Brandon C Parrish; Thomas R Katona; Serkis C Isikbay; Kelton T Stewart; Katherine S Kula
Journal:  Angle Orthod       Date:  2011-07-28       Impact factor: 2.079

4.  Bracket bond strength comparison between new unfilled experimental self-etching primer adhesive and conventional filled adhesives.

Authors:  Masahiro Iijima; Shuichi Ito; Takeshi Muguruma; Takashi Saito; Itaru Mizoguchi
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

5.  Shear Strength of Brackets Bonded with Universal Adhesive Containing 10-MDP after 20,000 Thermal Cycles.

Authors:  Mariana Almeida Mello Proença; Karime Tavares Lima da Silva; Alisson Costa E Silva; Edilausson Moreno Carvalho; José Bauer; Ceci Nunes Carvalho
Journal:  Int J Dent       Date:  2020-02-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.