Literature DB >> 17683048

A practical guide to nano-LC troubleshooting.

Marek Noga1, Filip Sucharski, Piotr Suder, Jerzy Silberring.   

Abstract

Capillary LC is one of the most powerful analytical tools available for separation scientists. Its unique analytical properties are associated with numerous technical issues that may cause operation of such systems to be somehow troublesome. Because of that, a good experience in capillary LC troubleshooting is required to keep the system in shape and, in effect, to obtain reliable results. In this paper, we summarize the most important issues of the capillary systems, including void and dead volumes, leakages, sample injection, and a multidimensional LC approach. The aim of this paper was to provide practical advise on system diagnosis, and to present solutions to problems discussed. Also, several exemplary nano-LC separations are included to demonstrate some typical problems encountered in our daily work.

Mesh:

Substances:

Year:  2007        PMID: 17683048     DOI: 10.1002/jssc.200700225

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  7 in total

1.  Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

Authors:  Yong Seok Choi; Kelvin H Lee
Journal:  Arch Pharm Res       Date:  2015-09-24       Impact factor: 4.946

2.  Sensitive, High-Throughput, and Robust Trapping-Micro-LC-MS Strategy for the Quantification of Biomarkers and Antibody Biotherapeutics.

Authors:  Ming Zhang; Bo An; Yang Qu; Shichen Shen; Wei Fu; Yuan-Ju Chen; Xue Wang; Rebeccah Young; John M Canty; Joseph P Balthasar; Keeley Murphy; Debadeep Bhattacharyya; Jonathan Josephs; Luca Ferrari; Shaolian Zhou; Surendra Bansal; Faye Vazvaei; Jun Qu
Journal:  Anal Chem       Date:  2018-01-08       Impact factor: 6.986

3.  Analysis of the urinary peptidome associated with Helicobacter pylori infection.

Authors:  Di Xiao; Fan-Liang Meng; Li-Hua He; Yi-Xin Gu; Jian-Zhong Zhang
Journal:  World J Gastroenterol       Date:  2011-02-07       Impact factor: 5.742

4.  Trap column-based intact mass spectrometry for rapid and accurate evaluation of protein molecular weight.

Authors:  Gyu-Min Lim; Byung-Gee Kim; Hee-Jin Jeong
Journal:  RSC Adv       Date:  2022-05-24       Impact factor: 4.036

5.  Systematic Investigation of LC Miniaturization to Increase Sensitivity in Wide-Target LC-MS-Based Trace Bioanalysis of Small Molecules.

Authors:  Veronika Fitz; Yasin El Abiead; Daniel Berger; Gunda Koellensperger
Journal:  Front Mol Biosci       Date:  2022-07-18

6.  Microfluidic Chip-LC/MS-based Glycomic Analysis Revealed Distinct N-glycan Profile of Rat Serum.

Authors:  Wei-Na Gao; Lee-Fong Yau; Liang Liu; Xing Zeng; Da-Can Chen; Min Jiang; Ju Liu; Jing-Rong Wang; Zhi-Hong Jiang
Journal:  Sci Rep       Date:  2015-08-07       Impact factor: 4.379

7.  Bioactivity Profiling of Small-Volume Samples by Nano Liquid Chromatography Coupled to Microarray Bioassaying Using High-Resolution Fractionation.

Authors:  Barbara M Zietek; Kristina B M Still; Kevin Jaschusch; Ben Bruyneel; Freek Ariese; Tinco J F Brouwer; Matthijs Luger; Rob J Limburg; Joost C Rosier; Dick J V Iperen; Nicholas R Casewell; Govert W Somsen; Jeroen Kool
Journal:  Anal Chem       Date:  2019-08-02       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.