Literature DB >> 17681408

Repair of fractures of the orbital floor with porous polyethylene implants.

Mustafa Yilmaz1, Haluk Vayvada, Enver Aydin, Adnan Menderes, Atay Atabey.   

Abstract

Our main aim was to evaluate the long-term results after reconstruction of the orbital floor with porous polyethylene implants. Twenty-six patients with fractures of the orbital floor were included in the study. The main cause of fractures was road crashes. They also complained of enophthalmos (n=19), diplopia (n=21), limited extrinsic ocular motility (n=17), impairment of the infraorbital nerve (n=18), and hypoglobus (n=9). All the fractures were reconstructed with thin and ultra-thin porous polyethylene sheets. No implants extruded and there were no signs of inflammatory reaction against the porous polyethylene. The symptoms were treated in 14 patients with enophthalmos, 18 with diplopia, 16 with limited extrinsic ocular motility, 14 with impairment of the infraorbital nerve and 8 with hypoglobus. Postoperative infections in four patients were treated with systemic antibiotics. Persistent ectropion was present in two patients. Porous polyethylene sheets are reliable, safe and effective implants and may be used for reconstruction of the orbital floor fracture with no donor site morbidity or need to fix implant.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17681408     DOI: 10.1016/j.bjoms.2007.06.004

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  12 in total

1.  Efficacy of Iliac Crest vs. Medpor in Orbital Floor Reconstruction.

Authors:  Hari Ram; R K Singh; Shadab Mohammad; Anup Kumar Gupta
Journal:  J Maxillofac Oral Surg       Date:  2010-09-23

2.  Survey of Common Practices among Oculofacial Surgeons in the Asia-Pacific Region: Management of Orbital Floor Blowout Fractures.

Authors:  Victor Koh; Nathalie Chiam; Gangadhara Sundar
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-03-17

3.  Reconstruction of Orbital Floor Fractures with Porous Polyethylene Implants: A Prospective Study.

Authors:  Degala Sai Krishna; Dey Soumadip
Journal:  J Maxillofac Oral Surg       Date:  2015-09-21

4.  Delayed immediate surgery for orbital floor fractures: Less can be more.

Authors:  David T Tang; Jan F Lalonde; Donald H Lalonde
Journal:  Can J Plast Surg       Date:  2011

5.  Options in orbital floor reconstruction in blowout fractures: a review of ten cases.

Authors:  Premalatha Shetty; G Senthil Kumar; Mohan Baliga; Nakul Uppal
Journal:  J Maxillofac Oral Surg       Date:  2009-08-11

6.  Quality of life after reconstruction of traumatic orbital floor defects using titanium mesh and medpore: A randomised controlled trial.

Authors:  Sneha Gupta; Divya Mehrotra; Praveen Kumar Singh; Vignesh U; Sujay Bhave; Ravi Katrolia
Journal:  J Oral Biol Craniofac Res       Date:  2021-01-29

7.  Biomaterials in skull base surgery.

Authors:  Wolfgang Maier
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

8.  Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports.

Authors:  Orapan Aryasit; Danny S Ng; Alice S C Goh; Kyung In Woo; Yoon-Duck Kim
Journal:  BMC Ophthalmol       Date:  2016-07-07       Impact factor: 2.209

9.  Porous Polyethylene Coated with Functionalized Hydroxyapatite Particles as a Bone Reconstruction Material.

Authors:  H Fouad; Randa AlFotawi; Othman Y Alothman; Basheer A Alshammari; Musaad Alfayez; Mohamed Hashem; Amer Mahmood
Journal:  Materials (Basel)       Date:  2018-03-29       Impact factor: 3.623

Review 10.  Management of orbital fractures: challenges and solutions.

Authors:  Jennings R Boyette; John D Pemberton; Juliana Bonilla-Velez
Journal:  Clin Ophthalmol       Date:  2015-11-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.