Abstract

UNLABELLED: Haemovigilance is defined as the collection of information on complications of transfusion, the analysis of the data, and suggestions for improvement in the transfusion service. A national haemovigilance system is of value in identifying possible areas in need of improvement in the national transfusion system. Haemovigilance becomes even more important if the system is used to compare the situation in one country with the situation in other countries, e.g. if the countries differ significantly in products used. The current study focuses on immunological transfusion complications, especially TRALI, as published in haemovigilance reports from Denmark, Norway, Sweden and the UK.
RESULTS: In Norway immunological transfusion reactions occurred 96.7 times per 100 000 red cell (RBC) transfusion, 231.1 times per 100 000 thrombocyte (Trc) concentrate transfusion and five times per 100.000 transfusions of solvent detergent treated plasma (SD plasma). Denmark and the UK have similar rates of transfusion reactions to RBC and fresh frozen plasma (FFP), but quite different for Trc (0.5 vs. 4.9 per 100 000). In 49% of reported TRALI the causative product is FFP, but no case of TRALI after SD plasma transfusion has been reported. DISCUSSION: When considering all reports for immunological complications in Norway, the most striking is the very small number of reports related to SD plasma. Comparing data from Denmark and the UK shows a big difference in reactions caused by thrombocyte concentrates that may reflect different production methods in the two countries. TRALI is most often caused by FFP, but has never been reported after SD plasma transfusion. Heamovigilance data can be valuable in choosing the safest products available.

Mesh:

Substances:

Year:  2007        PMID: 17676435     DOI: 10.1007/s00134-007-2875-1

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  6 in total

Review 1.  Coagulation abnormalities in the trauma patient: the role of point-of-care thromboelastography.

Authors:  Eduardo Gonzalez; Fredric M Pieracci; Ernest E Moore; Jeffry L Kashuk
Journal:  Semin Thromb Hemost       Date:  2010-10-26       Impact factor: 4.180

Review 2.  Is solvent/detergent plasma better than standard fresh-frozen plasma? A systematic review and an expert consensus document.

Authors:  Marco Marietta; Massimo Franchini; M Lucia Bindi; Francesco Picardi; Matteo Ruggeri; Giustina De Silvestro
Journal:  Blood Transfus       Date:  2016-02-17       Impact factor: 3.443

Review 3.  Health Technology Assessment of pathogen reduction technologies applied to plasma for clinical use.

Authors:  Americo Cicchetti; Alexandra Berrino; Marina Casini; Paola Codella; Giuseppina Facco; Alessandra Fiore; Giuseppe Marano; Marco Marchetti; Emanuela Midolo; Roberta Minacori; Pietro Refolo; Federica Romano; Matteo Ruggeri; Dario Sacchini; Antonio G Spagnolo; Irene Urbina; Stefania Vaglio; Giuliano Grazzini; Giancarlo M Liumbruno
Journal:  Blood Transfus       Date:  2016-07       Impact factor: 3.443

Review 4.  Transfusion-related acute lung injury (TRALI): a clinical review with emphasis on the critically ill.

Authors:  Alexander B Benson; Marc Moss; Christopher C Silliman
Journal:  Br J Haematol       Date:  2009-08-05       Impact factor: 6.998

Review 5.  Blood still kills: six strategies to further reduce allogeneic blood transfusion-related mortality.

Authors:  Eleftherios C Vamvakas; Morris A Blajchman
Journal:  Transfus Med Rev       Date:  2010-04

Review 6.  Transfusion-related acute lung injury (TRALI): current concepts and misconceptions.

Authors:  Christopher C Silliman; Yoke Lin Fung; J Bradley Ball; Samina Y Khan
Journal:  Blood Rev       Date:  2009-08-20       Impact factor: 8.250