Literature DB >> 17674341

PIV validation of blood-heart valve leaflet interaction modelling.

R Kaminsky1, K Dumont, H Weber, M Schroll, P Verdonck.   

Abstract

The aim of this study was to validate the 2D computational fluid dynamics (CFD) results of a moving heart valve based on a fluid-structure interaction (FSI) algorithm with experimental measurements. Firstly, a pulsatile laminar flow through a monoleaflet valve model with a stiff leaflet was visualized by means of Particle Image Velocimetry (PIV). The inflow data sets were applied to a CFD simulation including blood-leaflet interaction. The measurement section with a fixed leaflet was enclosed into a standard mock loop in series with a Harvard Apparatus Pulsatile Blood Pump, a compliance chamber and a reservoir. Standard 2D PIV measurements were made at a frequency of 60 bpm. Average velocity magnitude results of 36 phase-locked measurements were evaluated at every 10 degrees of the pump cycle. For the CFD flow simulation, a commercially available package from Fluent Inc. was used in combination with inhouse developed FSI code based on the Arbitrary Lagrangian-Eulerian (ALE) method. Then the CFD code was applied to the leaflet to quantify the shear stress on it. Generally, the CFD results are in agreement with the PIV evaluated data in major flow regions, thereby validating the FSI simulation of a monoleaflet valve with a flexible leaflet. The applicability of the new CFD code for quantifying the shear stress on a flexible leaflet is thus demonstrated.

Entities:  

Mesh:

Year:  2007        PMID: 17674341     DOI: 10.1177/039139880703000712

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  4 in total

1.  Fluid-Structure Interactions of the Mitral Valve and Left Heart: Comprehensive Strategies, Past, Present and Future.

Authors:  Daniel R Einstein; Facundo Del Pin; Xiangmin Jiao; Andrew P Kuprat; James P Carson; Karyn S Kunzelman; Richard P Cochran; Julius M Guccione; Mark B Ratcliffe
Journal:  Int J Numer Methods Eng       Date:  2010-03       Impact factor: 3.477

2.  A coupled sharp-interface immersed boundary-finite-element method for flow-structure interaction with application to human phonation.

Authors:  X Zheng; Q Xue; R Mittal; S Beilamowicz
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

Review 3.  Computational Fluid Dynamics and Additive Manufacturing to Diagnose and Treat Cardiovascular Disease.

Authors:  Amanda Randles; David H Frakes; Jane A Leopold
Journal:  Trends Biotechnol       Date:  2017-09-21       Impact factor: 19.536

4.  Hemodynamic Modeling of Biological Aortic Valve Replacement Using Preoperative Data Only.

Authors:  Florian Hellmeier; Jan Brüning; Simon Sündermann; Lina Jarmatz; Marie Schafstedde; Leonid Goubergrits; Titus Kühne; Sarah Nordmeyer
Journal:  Front Cardiovasc Med       Date:  2021-02-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.