Literature DB >> 17673357

Statistical variations of ultrasound signals backscattered from flowing blood.

Chih-Chung Huang1, Shyh-Hau Wang.   

Abstract

The statistical distributions of ultrasonic signals backscattered from blood have recently been used to characterize hemodynamic properties, such as red blood cell (RBC) aggregation and blood coagulation. However, a thorough understanding of the relationship between blood properties and the statistical behavior of signals backscattered from flowing blood is still lacking. This prompted us to use the statistical parameter to characterize signals backscattered from both whole blood and RBC suspensions at different flow velocities (from 10 to 60 cm/s) and hematocrits (from 20% to 50%) under a steady laminar flow condition. The Nakagami parameter, scaling parameter, backscatter amplitude profile and flow velocity profile across a flow tube were acquired using a 10 MHz focused ultrasonic transducer. The backscattered signal peaked approximately at the centerline of the flow tube due to the effects of RBC aggregation, with the peak value increasing as the flow velocity of whole blood decreased. The Nakagami parameter increased from 0.45 to 0.78 as the flow velocity increased from 10 to 60 cm/s. The probability density function (PDF) of signals backscattered from flowing whole blood conformed with a pre-Rayleigh distribution. The Nakagami parameter was close to 1 for signals backscattered from RBC suspensions at all the flow velocities and hematocrits tested, for which the PDF was Rayleigh distributed. These differences in the statistical distributions of backscattered signals between whole blood and RBC suspensions suggest that variations in the size of dynamic scatterers in the flow affect the shape of the backscattered signal envelope, which should be considered in future statistical models used to characterize blood properties.

Entities:  

Mesh:

Year:  2007        PMID: 17673357     DOI: 10.1016/j.ultrasmedbio.2007.06.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Evaluation of thrombolysis by using ultrasonic imaging: an in vitro study.

Authors:  Jui Fang; Po-Hsiang Tsui
Journal:  Sci Rep       Date:  2015-07-01       Impact factor: 4.379

2.  Ultrasound characterization of the mastoid for detecting middle ear effusion: A preliminary clinical validation.

Authors:  Chin-Kuo Chen; Jui Fang; Yung-Liang Wan; Po-Hsiang Tsui
Journal:  Sci Rep       Date:  2016-06-09       Impact factor: 4.379

Review 3.  Basic concept and clinical applications of quantitative ultrasound (QUS) technologies.

Authors:  Tadashi Yamaguchi
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314