Literature DB >> 17673269

Laboratory evaluation of a simple and rapid latex agglutination assay for the serodiagnosis of typhoid fever.

Theresia H Abdoel1, Rob Pastoor, Henk L Smits, Mochammad Hatta.   

Abstract

A latex agglutination assay for the serodiagnosis of typhoid fever was evaluated on samples collected from patients with clinical suspicion of typhoid fever in South Sulawesi, Indonesia, where the disease is endemic. The latex assay is very easy to use, gives a rapid result and may be used as a point-of-care diagnostic test. For acute phase samples collected on average 6 days after the onset of illness, the sensitivity is 42.5% for culture-confirmed patients with typhoid fever and the specificity is 96.9%. The sensitivity improved with the duration of illness from 30.8% for samples collected during the first 4-5 days of illness to 45.5% for samples collected between days 7 and 9, and to 84.6% for the samples collected more than 9 days after the onset of illness. Testing of follow-up samples may further improve sensitivity by demonstrating seroconversion.

Entities:  

Mesh:

Year:  2007        PMID: 17673269     DOI: 10.1016/j.trstmh.2007.05.020

Source DB:  PubMed          Journal:  Trans R Soc Trop Med Hyg        ISSN: 0035-9203            Impact factor:   2.184


  8 in total

Review 1.  Temporal dimension in reference standard misclassification - a concept note.

Authors:  S A Rizwan; Baridalyne Nongkynrih; S Lena Charlette; Anand Krishnan
Journal:  J Clin Diagn Res       Date:  2014-07-20

2.  Development of a Simple, Peripheral-Blood-Based Lateral-Flow Dipstick Assay for Accurate Detection of Patients with Enteric Fever.

Authors:  Iqbal Hassan Khan; M Abu Sayeed; Nishat Sultana; Kamrul Islam; Jakia Amin; M Omar Faruk; Umama Khan; Farhana Khanam; Edward T Ryan; Firdausi Qadri
Journal:  Clin Vaccine Immunol       Date:  2016-05-06

3.  Analysis of characteristics of paratyphoid A in 157 Chinese inpatients between 1998 and 2009.

Authors:  F Yu; S Fan; X Fan; P Dong; X Wang; Y Chen; J Li
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-09-09       Impact factor: 3.267

Review 4.  Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

Authors:  Lalith Wijedoru; Sue Mallett; Christopher M Parry
Journal:  Cochrane Database Syst Rev       Date:  2017-05-26

5.  A one-step homogeneous sandwich immunosensor for Salmonella detection based on magnetic nanoparticles (MNPs) and quantum Dots (QDs).

Authors:  Hua Kuang; Gang Cui; Xiujin Chen; Honghong Yin; Qianqian Yong; Liguang Xu; Chifang Peng; Libing Wang; Chuanlai Xu
Journal:  Int J Mol Sci       Date:  2013-04-22       Impact factor: 5.923

6.  Development of a novel rapid immunodiagnostic kit based on flagellar 40 kDa antigen epitope for the detection of typhoid fever in Indian patients.

Authors:  Rahul Mitra; Surya Bhan; Gopal Nath; Narender Kumar; Ziledar Ali
Journal:  ScientificWorldJournal       Date:  2013-02-05

7.  A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

Authors:  Helen L Storey; Ying Huang; Chris Crudder; Allison Golden; Tala de los Santos; Kenneth Hawkins
Journal:  PLoS One       Date:  2015-11-13       Impact factor: 3.240

8.  Instrument-Free and Visual Detection of Salmonella Based on Magnetic Nanoparticles and an Antibody Probe Immunosensor.

Authors:  Liding Zhang; Xuewei Du; Zhixin Chen; Congjie Chen; Nanxin Gong; Yihao Song; Yuzhu Song; Qinqin Han; Xueshan Xia; Haiming Luo; Jinyang Zhang
Journal:  Int J Mol Sci       Date:  2019-09-19       Impact factor: 5.923

  8 in total