Literature DB >> 17671659

Environmental applications of single collector high resolution ICP-MS.

Michael Krachler1.   

Abstract

The number of environmental applications of single collector high resolution ICP-MS (HR-ICP-MS) has increased rapidly in recent years. There are many factors that contribute to make HR-ICP-MS a very powerful tool in environmental analysis. They include the extremely low detection limits achievable, tremendously high sensitivity, the ability to separate ICP-MS signals of the analyte from spectral interferences, enabling the reliable determination of many trace elements, and the reasonable precision of isotope ratio measurements. These assets are improved even further using high efficiency sample introduction systems. Therefore, external factors such as the stability of laboratory blanks are frequently the limiting factor in HR-ICP-MS analysis rather than the detection power. This review aims to highlight the most recent applications of HR-ICP-MS in this sector, focusing on matrices and applications where the superior capabilities of the instrumental technique are most useful and often ultimately required.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17671659     DOI: 10.1039/b703823m

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  4 in total

1.  Characterization of the elemental composition of newborn blood spots using sector-field inductively coupled plasma-mass spectrometry.

Authors:  Erica K Langer; Kimberly J Johnson; Martin M Shafer; Patrick Gorski; Joel Overdier; Jessica Musselman; Julie A Ross
Journal:  J Expo Sci Environ Epidemiol       Date:  2010-06-30       Impact factor: 5.563

2.  The distribution of Mn2+ in rabbit eyes after topical administration for manganese-enhanced MRI.

Authors:  Shenzhi Liang; Miao Liang; Yu Zhu; Jingliang Cheng; Zitao Yang
Journal:  Int J Clin Exp Pathol       Date:  2015-01-01

3.  [Metal ion concentrations in patients with metal-metal bearings in prostheses].

Authors:  J P Kretzer; C Van Der Straeten; R Sonntag; U Müller; M Streit; B Moradi; S Jäger; J Reinders
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

4.  Determination of 16 selected trace elements in children plasma from china economical developed rural areas using high resolution magnetic sector inductively coupled mass spectrometry.

Authors:  Xiaobing Liu; Jianhua Piao; Zhenwu Huang; Shuang-Qing Zhang; Weidong Li; Yuan Tian; Xiaoguang Yang
Journal:  J Anal Methods Chem       Date:  2014-02-20       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.