Literature DB >> 17671008

Intraobserver and interobserver reliability of two ultrasound measures of humeral head position in infants with neonatal brachial plexus palsy.

Torpon Vathana1, Stace' Rust, Janith Mills, David Wilkes, Richard Browne, Peter R Carter, Marybeth Ezaki.   

Abstract

BACKGROUND: Ultrasonographic evaluation of the hip in infants is considered both reliable and reproducible in the diagnosis of developmental dysplasia of the hip. Ultrasonographic evaluation of the shoulder in infants has been reported as a valuable diagnostic aid in dysplastic development following neonatal brachial plexus palsy. To our knowledge, there has been no study of the intraobserver reproducibility and interobserver reliability of sonography of the shoulder in infants with and without suspected posterior shoulder dislocation.
METHODS: Two identical but randomly ordered sets of the same deidentified sonographic images of shoulders in infants were given to radiologists, pediatric orthopaedists and orthopaedic residents, and fellows with varying degrees of experience in the evaluation of shoulder pathology in infants, who measured the position of the humeral head relative to the axis of the scapula. Intraobserver reproducibility and interobserver reliability of the measurements were assessed.
RESULTS: For the position of the humeral head with respect to the glenoid in both normal and abnormal conditions, the Pearson correlation coefficient for intraobserver reproducibility was 0.91 and the intraclass correlation coefficient for interobserver reliability was 0.875. For estimating the percentage of the humeral head posterior to the axis of the scapula, the Pearson correlation was 0.85 and the intraclass correlation coefficient was 0.77.
CONCLUSIONS: Ultrasonographic examination of the shoulder in infants to assess for the position of the humeral head with respect to the scapula showed high intraobserver reproducibility and interobserver reliability. It is recommended as a reliable technique for evaluating shoulder position in infants with neonatal brachial plexus palsy.

Entities:  

Mesh:

Year:  2007        PMID: 17671008     DOI: 10.2106/JBJS.F.01263

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  Utility of ultrasound in noninvasive preoperative workup of neonatal brachial plexus palsy.

Authors:  Deepak K Somashekar; Michael A Di Pietro; Jacob R Joseph; Lynda J-S Yang; Hemant A Parmar
Journal:  Pediatr Radiol       Date:  2015-12-30

Review 2.  The current role of diagnostic imaging in the preoperative workup for refractory neonatal brachial plexus palsy.

Authors:  Deepak K Somashekar; Thomas J Wilson; Michael A DiPietro; Jacob R Joseph; Mohannad Ibrahim; Lynda J-S Yang; Hemant A Parmar
Journal:  Childs Nerv Syst       Date:  2016-05-14       Impact factor: 1.475

Review 3.  Arthroscopic treatment for internal contracture of the shoulder secondary to brachial plexus birth palsy: report of a case series and review of the literature.

Authors:  Pablo Andrés-Cano; Miguel Ángel Toledo; David Michael Farrington; Juan José Gil
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-14

4.  An early shoulder repositioning program in birth-related brachial plexus injury: a pilot study of the Sup-ER protocol.

Authors:  Cynthia Verchere; Kim Durlacher; Doria Bellows; Jeffrey Pike; Marija Bucevska
Journal:  Hand (N Y)       Date:  2014-06

5.  What is the Interobserver Reliability of an Ultrasound-enhanced Physical Examination of the Hip in Infants? A Prospective Study on the Ease of Acquiring Skills to Diagnose Hip Dysplasia.

Authors:  Neha Jejurikar; León Moscona-Mishy; Mónica Rubio; Romina Cavallaro; Pablo Castañeda
Journal:  Clin Orthop Relat Res       Date:  2021-09-01       Impact factor: 4.755

  5 in total